Best Quality 20kw DC96V Single Phase Pure Sine Wave Inverter

Best Quality 20kw DC96V Single Phase Pure Sine Wave Inverter

Energy Producers Ltd
Kategorie:
2026-04-05

Przegląd projektów

Podobała Ci się ta praca? Podziel się

Opis produktu

Opis produktu

Power Frequency Pure Sine Wave Inverter Features:

1.Complete isolation-type inverter technology, noiseless output.

2.Adoption of advanced SPWM technology, pure sine wave output.

3.Dynamic current loop control technology to ensure inverter reliable operation.

4.Wide DC input voltage range.

5.Excellent EMC design.

6.Low output harmonic distortion (THD≤3%).

7.LED indicators for input voltage range, load power range, normal output & failure state.

8.Optional energy saving mode.

9.Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage, over-temperature, and inverter’s inner fault identification protections.

10.Wide working temperature range (industrial level).
11.Continuous operation at full power.
Application
1. For desolate area like mountain, island, pasturing area, etc.
2. For transportation system like beacon light, traffic light, street light, etc.
3. For communication system: unattached operation microwave middle   station, optical
cable maintenance station, etc.
4. For photovoltaic power station, wind-solar power station, park charging station, family
   power house, factory power station, etc.
5. For solar building: has good business future.
6. For the new technology application project.


                                                                  
off grid solar power system
 

                                                              off grid wind turbine power system 

Szczegółowe zdjęcia

Parametry produktu

 

20KW off grid single phase inverter technical parameters

Model NB96-20KDZ
Wejście DC Wejściowe napięcie znamionowe 96VDC
Wejściowy prąd znamionowy 231.5A
Dopuszczalny zakres napięcia wejściowego DC 80-124VDC
Obejście AC Dozwolony zakres napięcia wejściowego 220 VAC ± 15%
Wejściowy prąd znamionowy 90.9A
Czas transferu obejścia ≤40ms(4ms optional)
Wyjście AC Pojemność znamionowa 20KW
Wyjściowe napięcie znamionowe i częstotliwość 220 VAC 50Hz / 60Hz
Prąd znamionowy wyjścia 90.9A
Dokładność napięcia wyjściowego 220 VAC± 2%
Dokładność częstotliwości wyjściowej 50Hz / 60Hz ± 0.05%
Fala Pure sine wave   (Isolation transformer)
THD. ≤3%(Linear load)
Współczynnik mocy (PF) 1
Przeciążalność 120%,10minutes,200%,10 second
Współczynnik szczytu (CF) 3:1
Wydajność falownika >90%
Środowisko pracy Wytrzymałość dielektryczna 1500VAC,1minute
Hałas (1 m) ≤50dB
Temperatura otoczenia -10ºC~+50ºC
Wilgotność 0~90%, bez kondensacji
Wysokość <3000m
Higher than 3000m rated power should be reduced
Funkcja produkcji Zabezpieczenie przed cofnięciem sygnału wejściowego, zabezpieczenie przed zbyt niskim napięciem wejściowym, zabezpieczenie przed przeciążeniem wyjścia, zabezpieczenie przed zwarciem wyjścia, zabezpieczenie termiczne
Interfejs komunikacyjny RS485/WIFI/GPRS/Ethernet (opcjonalnie)
Ładowarka sieciowa  (opcjonalnie)
Bateria, priorytet sieci miejskiej (generator) (opcjonalnie)
Rozmiar 550*1060*1300mm
Waga 250kg

20KW off grid three phase inverter technical parameters

Typ NB216-20KSZ
Wejście DC Wejściowe napięcie znamionowe 216VDC
Wejściowy prąd znamionowy 102.9A
Dopuszczalny zakres napięcia wejściowego DC 180-280VDC
Obejście AC Dozwolony zakres napięcia wejściowego 380VAC± 15% VAC
Wejściowy prąd znamionowy 30.4A
Czas transferu obejścia ≤100ms(4ms optional)
Wyjście AC Pojemność znamionowa 20KW
Wyjściowe napięcie znamionowe i częstotliwość Three phase 380VAC,50Hz/60HZ
Prąd znamionowy wyjścia 30.4A
Dokładność napięcia wyjściowego 380VAC ± 2%
Dokładność częstotliwości wyjściowej 50Hz ± 0.05%
Fala Pure sine wave  (Isolation transformer)
THD. ≤3%(Linear load)
Współczynnik mocy (PF) 1
Przeciążalność 120%, 10 minut
Wydajność nadprądowa 200%,10 sekund
Współczynnik szczytu (CF) 3:1
Wydajność falownika >92%
Środowisko pracy Wytrzymałość dielektryczna 1500VAC,1minute
Hałas (1 m) ≤50dB
Temperatura otoczenia -10ºC~+50ºC
Wilgotność 0~90%, bez kondensacji
Wysokość <2000m
Higher than 2000m rated power should be reduced
Funkcja produkcji Zabezpieczenie przed cofnięciem sygnału wejściowego, zabezpieczenie przed zbyt niskim napięciem wejściowym, zabezpieczenie przed przeciążeniem wyjścia, zabezpieczenie przed zwarciem wyjścia, zabezpieczenie termiczne
Interfejs komunikacyjny RS485/WIFI/GPRS/Ethernet (opcjonalnie)
Ładowarka sieciowa  (opcjonalnie)
Bateria, priorytet sieci miejskiej (generator) (opcjonalnie)
Rozmiar 550×1050×1340mm
Waga 220KG

50KW off grid three phase inverter technical parameters

Typ NB384-50KSZ
Wejście DC Wejściowe napięcie znamionowe 384VDC
Wejściowy prąd znamionowy 144.7A
Dopuszczalny zakres napięcia wejściowego DC 320-480VDC
Obejście AC Dozwolony zakres napięcia wejściowego 380VAC± 15% VAC
Wejściowy prąd znamionowy 76A
Czas transferu obejścia ≤100ms(4ms optional)
Wyjście AC Moc znamionowa wyjścia 50KW
Wyjściowe napięcie znamionowe i częstotliwość Three phase 380VAC,50HZ
(Three phase four wire)
Prąd znamionowy wyjścia 76A
Dokładność napięcia wyjściowego 380VAC ± 2%
Dokładność częstotliwości wyjściowej 50Hz ± 0.05%
Fala Pure sine wave  (Isolation transformer)
THD. ≤3%(Linear load)
Współczynnik mocy (PF) 1
Przeciążalność 120%, 10 minut
Wydajność nadprądowa Specyfikacje

th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Customization:’, ‘Available’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Nature of Source Flow:’, ‘Passive inverter’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Certyfikacja:’, ‘ISO9001, RoHS, CE’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Model’, ‘NB96-20KDZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DC input’, ‘Input rated voltage’, ’96VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘231.5A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage allowing range’, ’80-124VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC Bypass’, ‘Allow input voltage range’, ‘220 VAC ± 15%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘90.9A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Bypass transfer time’, ‘≤40ms(4ms optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC output’, ‘Rated capacity’, ’20KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated voltage and frequency’, ‘220 VAC 50Hz / 60Hz’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated current’, ‘90.9A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage accuracy’, ‘220 VAC± 2%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ’50Hz / 60Hz ± 0.05%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wave’, ‘Pure sine wavexa0xa0 (Isolation transformer)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD.’, ‘≤3%(Linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor (PF)’, ‘1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,10minutes,200%,10 second’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Crest factor (CF)’, ‘3:1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter efficiency’, ‘>90%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working Environment’, ‘Dielectric strength’, ‘1500VAC,1minute’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘≤50dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ambient temperature’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Humidity’, ‘0~90%,No condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude’, ‘<3000m Higherxa0thanxa03000m ratedxa0powerxa0shouldxa0bexa0reduced’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Production function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ac charger’, ‘(optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Battery, City grid (generator) priority’, ‘(optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size’, ‘550*1060*1300mm’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight’, ‘250kg’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Type’, ‘NB216-20KSZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DC input’, ‘Input rated voltage’, ‘216VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘102.9A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage allowing range’, ‘180-280VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC bypass’, ‘Allow input voltage range’, ‘380VAC± 15% VAC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘30.4A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Bypass transfer time’, ‘≤100ms(4ms optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC output’, ‘Rated capacity’, ’20KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated voltage and frequency’, ‘Three phase 380VAC,50Hz/60HZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated current’, ‘30.4A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage accuracy’, ‘380VAC ± 2%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ’50Hz ± 0.05%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wave’, ‘Pure sine wavexa0 (Isolation transformer)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD.’, ‘≤3%(Linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor (PF)’, ‘1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,10 minutes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%,10 seconds’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Crest factor (CF)’, ‘3:1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter efficiency’, ‘>92%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working Environment’, ‘Dielectric strength’, ‘1500VAC,1minute’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘≤50dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ambient temperature’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Humidity’, ‘0~90%, No condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude’, ‘<2000m Higherxa0thanxa02000m ratedxa0powerxa0shouldxa0bexa0reduced’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Production function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ac charger’, ‘(optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Battery, City grid (generator) priority’, ‘(optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size’, ‘550×1050×1340mm’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight’, ‘220KG’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Type’, ‘NB384-50KSZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DC input’, ‘Input rated voltage’, ‘384VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘144.7A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage allowing range’, ‘320-480VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC bypass’, ‘Allow input voltage range’, ‘380VAC± 15% VAC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ’76A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Bypass transfer time’, ‘≤100ms(4ms optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC output’, ‘Output rated power’, ’50KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated voltage and frequency’, ‘Three phase 380VAC,50HZ(Three phase four wire)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated current’, ’76A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage accuracy’, ‘380VAC ± 2%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ’50Hz ± 0.05%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wave’, ‘Pure sine wavexa0 (Isolation transformer)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD.’, ‘≤3%(Linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor (PF)’, ‘1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,10 minutes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%,10 seconds’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Crest factor (CF)’, ‘3:1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter efficiency’, ‘>92%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working Environment’, ‘Dielectric strength’, ‘1500VAC,1minute’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘≤50dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ambient temperature’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Humidity’, ‘0~90%, No condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude’, ‘<2000m Higherxa0thanxa02000m ratedxa0powerxa0shouldxa0bexa0reduced’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Production function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ac charger’, ‘(optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Battery, City grid (generator) priority’, ‘(optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size’, ‘630*1310*1573mm’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight’, ‘430KG’]

Kluczowe cechy

  • Producent/fabryka i firma handlowa: Producent/fabryka i firma handlowa