50kw 100kw 200kw 300kw on Grid Wind Turbine Charge Controller Grid-Tied Wind Generator Charge Controller

50kw 100kw 200kw 300kw on Grid Wind Turbine Charge Controller Grid-Tied Wind Generator Charge Controller

Energieproducenten Ltd
Categorieën:
2026-04-05

Overzicht projecten

Vond je dit werk leuk? Delen

Product Beschrijving

On grid wind turbine controller WGMC50K380 WGMC100K380 WGMC200K380
Wind turbine input
Stroom 50KW 100KW 200KW
Max. Control power 100KW 200KW 400KW
Rated voltage of wind turbine (AC) 380V/400V 380V/400V 380V/400V
Bereik ingangsspanning AC 0600V AC 0600V AC 0600V
DC 0900V DC 0900V DC 0900V
Braking voltage (DC) 550V±1% 550V±1% 550V±1%
Braking time min 1020 min
Handmatige bediening Manual brake
Automatische controlefunctie Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake
DC output parameters
Output voltage range (DC) 0-550V 0-550V 0-550V
Constant voltage (DC) 520V±1% 520V±1% 520V±1%
On grid wind turbine inverter DMWG50K DMWG100K DMWG200K
Nominaal uitgangsvermogen (AC) 50KW 100KW 200KW
Max. Output power (AC) 55KW 110KW 220KW
Bereik ingangsspanning (DC) 0-800V 0-800V 0-800V
MPPT Voltage range (DC) 150V-700V 150V-700V 150V-700V
Max. Ingangsstroom (DC) 114.6A 229A 458.3A
Nominale stroom 104A 208A 416.7A
THD Current harmonic <3%(at rated power)
Vermogensfactor >0.99
Max. efficiency 96%
Allowable grid voltage range (AC) 220V/380V/440V/480V (Three-phase)±20%
Toelaatbaar netfrequentiebereik 50Hz/60Hz±10%
Automatic operation conditions DC input and power grid meet the requirements, and the inverter operates automatically
Restart time after power failure 5min (adjustable)
General parameters
Functie Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting
Automatic protection Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester
Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc
Weergave Touch screen, LCD
Monitoring content Fan voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed
Protection level IP20(Indoor)IP65 (Outdoors)
Telematics RS485/USB/GPRS/WIFI/Ethernet (optional)
Environment Operating amb. Temp. & Hum  -30-60°C,<90% no condensation
Geluid (1m) <40 dB
Refrigeration mode Geforceerde luchtkoeling
Size / weight
Controller size / weight 500*500*900mm   56kg 600*500*1200mm    107kg 950*550*1700mm    150kg
Dump load size / weight 920*770*380mm   80kg 920*770*380mm*2   150kg    923*739*510mm*4   280kg
Inverter size / weight 750*600*1320mm  340kg 1460*860*1820mm   1.4t 1460*860*1820mm   1.6t

     

* Above parameter only for reference

Could be custom made according to user’s requirements.

Specificaties

th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Aanpassing:’, ‘Beschikbaar’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Service na verkoop:’, ‘Provide’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Garantie:’, ‘1 Jaar’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘On grid wind turbine controller’, ‘WGMC50K380’, ‘WGMC100K380’, ‘WGMC200K380’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power’, ’50KW’, ‘100KW’, ‘200KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. Control power’, ‘100KW’, ‘200KW’, ‘400KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated voltage of wind turbine (AC)’, ‘380V/400V’, ‘380V/400V’, ‘380V/400V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input voltage range’, ‘AC 0-600V’, ‘AC 0-600V’, ‘AC 0-600V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DC 0-900V’, ‘DC 0-900V’, ‘DC 0-900V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Braking voltage (DC)’, ‘550V±1%’, ‘550V±1%’, ‘550V±1%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Braking time min’, ’10-20 min’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Manual control’, ‘Manual brake’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic control function’, ‘Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage range (DC)’, ‘0-550V’, ‘0-550V’, ‘0-550V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Constant voltage (DC)’, ‘520V±1%’, ‘520V±1%’, ‘520V±1%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘On grid wind turbine inverter’, ‘DMWG50K’, ‘DMWG100K’, ‘DMWG200K’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated output powerxa0(AC)’, ’50KW’, ‘100KW’, ‘200KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. Output powerxa0(AC)’, ’55KW’, ‘110KW’, ‘220KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input voltage rang (DC)’, ‘0-800V’, ‘0-800V’, ‘0-800V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘MPPT Voltage range (DC)’, ‘150V-700V’, ‘150V-700V’, ‘150V-700V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. Input currentxa0(DC)’, ‘114.6A’, ‘229A’, ‘458.3A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated current’, ‘104A’, ‘208A’, ‘416.7A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THDxa0Current harmonic’, ‘<3%(at rated power)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘>0.99’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. efficiency’, ‘96%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Allowable grid voltage range (AC)’, ‘220V/380V/440V/480Vxa0(Three-phase)±20%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Allowable grid frequency range’, ’50Hz/60Hz±10%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic operation conditions’, ‘DC input and power grid meet the requirements, and the inverter operates automatically’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Restart time after power failure’, ‘5min (adjustable)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Function’, ‘Rectification, DC output, output voltage control, output current control, Dumpxa0load control, control parameter setting, wind turbine curve setting’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic protection’, ‘Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display’, ‘Touch screen, LCD’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Monitoring content’, ‘Fan voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection level’, ‘IP20(Indoor)IP65 (Outdoors)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Telematics’, ‘RS485/USB/GPRS/WIFI/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Environment’, ‘Operating amb. Temp. & Hum xa0-30-60°C,<90% no condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ruis (1m)’, ‘<40dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Refrigeration mode’, ‘Forced air cooling’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Controller size / weight’, ‘500*500*900mm xa0xa056kg’, ‘600*500*1200mm xa0xa0xa0107kg’, ‘950*550*1700mm xa0xa0xa0150kg’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Dumpxa0load size / weight’, ‘920*770*380mm xa0xa080kg’, ‘920*770*380mm*2 xa0xa0150kg’, ‘923*739*510mm*4 xa0xa0280kg’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter size / weight’, ‘750*600*1320mm xa0340kg’, ‘1460*860*1820mm xa0xa01.4t’, ‘1460*860*1820mm xa0xa01.6t’]

Key Features

  • Manufacturer/Factory & Trading Company: Manufacturer/Factory & Trading Company