50kw 100kw 200kw 300kw on Grid Wind Turbine Charge Controller Grid-Tied Wind Generator Charge Controller

50kw 100kw 200kw 300kw on Grid Wind Turbine Charge Controller Grid-Tied Wind Generator Charge Controller

Energy Producers Ltd
Categorías:
2026-04-05

Proyectos generales

¿Te ha gustado esta obra? Compártelo

Descripción del producto

On grid wind turbine controller WGMC50K380 WGMC100K380 WGMC200K380
Wind turbine input
Potencia 50KW 100 KW 200 KW
Max. Control power 100 KW 200 KW 400KW
Rated voltage of wind turbine (CA) 380V/400V 380V/400V 380V/400V
Rango de tensión de entrada CA 0600V CA 0600V CA 0600V
DC 0900V DC 0900V DC 0900V
Braking voltage (DC) 550V±1% 550V±1% 550V±1%
Braking time min 1020 min
Control manual Manual brake
Función de control automático Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake
DC output parameters
Output voltage range (DC) 0-550V 0-550V 0-550V
Constant voltage (DC) 520V±1% 520V±1% 520V±1%
On grid wind turbine inverter DMWG50K DMWG100K DMWG200K
Potencia nominal de salida (CA) 50KW 100KW 200KW
Max. Output power (CA) 55KW 110KW 220KW
Rango de tensión de entrada (CC) 0-800V 0-800V 0-800V
MPPT Voltage range (DC) 150V-700V 150V-700V 150V-700V
Máx. Corriente de entrada (DC) 114.6A 229A 458.3A
Corriente nominal 104A 208A 416.7A
THD Corriente armónica <3%(at rated power)
Factor de potencia >0.99
Eficiencia máxima 96%
Rango de tensión de red admisible (AC) 220V/380V/440V/480V (Ttrifásico)±20%
Rango de frecuencia de red admisible 50Hz/60Hz±10%
Condiciones de funcionamiento automático DC input and power grid meet the requirements, and the inverter operates automatically
Tiempo de reinicio tras un corte de corriente 5min (adjustable)
Parámetros generales
Función Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting
Protección automática Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester
Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc
Mostrar Touch screen, LCD
Supervisión de contenidos Fan voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed
Nivel de protección IP20(Interior)IP65 (Exterior)
Telemática RS485/USB/GPRS/WIFI/Ethernet (optional)
Medio ambiente Temperatura y Hum. Temp. y Hum -30-60°C,<90% sin condensación
Ruido (1m) <40 dB
Modo refrigeración Refrigeración por aire forzado
Size / weight
Controller size / weight 500*500*900mm   56kg 600*500*1200mm    107kg 950*550*1700mm    150kg
Dump load size / weight 920*770*380mm   80kg 920*770*380mm*2   150kg    923*739*510mm*4   280kg
Inverter size / weight 750*600*1320mm  340kg 1460*860*1820mm   1.4t 1460*860*1820mm   1.6t

     

* Above parameter only for reference

Could be custom made according to user’s requirements.

Especificaciones

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Personalización:’, ‘Disponible’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘After-sales Service:’, ‘Provide’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Warranty:’, ‘1 Year’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘On grid wind turbine controller’, ‘WGMC50K380’, ‘WGMC100K380’, ‘WGMC200K380’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power’, ’50KW’, ‘100KW’, ‘200KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. Control power’, ‘100KW’, ‘200KW’, ‘400KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated voltage of wind turbine (AC)’, ‘380V/400V’, ‘380V/400V’, ‘380V/400V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input voltage range’, ‘AC 0-600V’, ‘AC 0-600V’, ‘AC 0-600V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DC 0-900V’, ‘DC 0-900V’, ‘DC 0-900V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Braking voltage (DC)’, ‘550V±1%’, ‘550V±1%’, ‘550V±1%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Braking time min’, ’10-20 min’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Manual control’, ‘Manual brake’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic control function’, ‘Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage range (DC)’, ‘0-550V’, ‘0-550V’, ‘0-550V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Constant voltage (DC)’, ‘520V±1%’, ‘520V±1%’, ‘520V±1%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘On grid wind turbine inverter’, ‘DMWG50K’, ‘DMWG100K’, ‘DMWG200K’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Potencia nominal de salidaxa0(AC)’, ’50KW’, ‘100KW’, ‘200KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. Output powerxa0(AC)’, ’55KW’, ‘110KW’, ‘220KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input voltage rang (DC)’, ‘0-800V’, ‘0-800V’, ‘0-800V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘MPPT Voltage range (DC)’, ‘150V-700V’, ‘150V-700V’, ‘150V-700V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. Input currentxa0(DC)’, ‘114.6A’, ‘229A’, ‘458.3A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated current’, ‘104A’, ‘208A’, ‘416.7A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THDxa0Current harmonic’, ‘<3%(at rated power)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Factor de potencia’, ‘>0,99’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Eficacia máx.’, ‘96%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rango de tensión de red admisible (CA)’, ‘220V/380V/440V/480Vxa0(Trifásica)±20%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rango de frecuencia de red admisible’, ’50Hz/60Hz±10%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic operation conditions’, ‘DC input and power grid meet the requirements, and the inverter operates automatically’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Restart time after power failure’, ‘5min (adjustable)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Function’, ‘Rectification, DC output, output voltage control, output current control, Dumpxa0load control, control parameter setting, wind turbine curve setting’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic protection’, ‘Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display’, ‘Touch screen, LCD’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Monitoring content’, ‘Fan voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Nivel de protección’, ‘IP20(Interior)IP65 (Exterior)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Telematics’, ‘RS485/USB/GPRS/WIFI/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Environment’, ‘Operating amb. Temp. & Hum xa0-30-60°C,<90% no condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ruido (1m)’, ‘<40dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Modo de refrigeración’, ‘Refrigeración por aire forzado’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Controller size / weight’, ‘500*500*900mm xa0xa056kg’, ‘600*500*1200mm xa0xa0xa0107kg’, ‘950*550*1700mm xa0xa0xa0150kg’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Dumpxa0load size / weight’, ‘920*770*380mm xa0xa080kg’, ‘920*770*380mm*2 xa0xa0150kg’, ‘923*739*510mm*4 xa0xa0280kg’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter size / weight’, ‘750*600*1320mm xa0340kg’, ‘1460*860*1820mm xa0xa01.4t’, ‘1460*860*1820mm xa0xa01.6t’]

Características principales

  • Fabricante/Fábrica y empresa comercial: Fabricante/Fábrica y empresa comercial