Versatile 300kw to 1000kw Ocean Power Generator Solutions3.

Versatile 300kw to 1000kw Ocean Power Generator Solutions3.

Energy Producers Ltd
Categories:
2026-04-05

Overview Projects

Did you like this Work? Please Share

Product Description

Generator power converterDMGC300KDMGC500KDMGC1000K
Generator rated power300KW500KW1000KW
Rated voltage of generator (AC)400V/690V400V/690V400V/690V
Input voltage range (AC)0550V/0-800V0550V/0-800V0550V/0-800V
Rated output power (AC)300KW500KW1000KW
MPPT MPPT Voltage range (AC)250-500V/400-750V250-500V/400-750V250-500V/400-750V
Max. Input current (AC)476A/276A794A/460A1588A/920A
Rated output current (AC)433A/251A722A/418A1444A/837A
THD Current harmonic <3%(At rated power)
 Power factor>0.99
 Max. efficiency96%
Electrical structurePower frequency transformer
 Allowable grid voltage range (AC)220V/380V/440V/480V (Three-phase) ±20%
 Allowable grid frequency range50Hz/60Hz±10%
 Automatic operation conditionsAC input and power grid meet the requirements, and the power converter operates automatically
 Restart time after power failure2min ( Adjustable)
General parameters
Function Rectification, wind turbine curve setting, adjustable output power
Automatic protectionReverse connection protection, short circuit protection, island effect protection, LVRT, overheat protection, overload protection, ground fault protection, lightning arrester, etc
DisplayTouch screen
Monitoring contentGenerator voltage, current, power, inverter output power, * cumulative power generation,
* power generation at any time
 Protection levelIP20(Indoor)IP65 (Outdoors)
Telematics RS485/USB/GPRS/WIFI/Ethernet (Optional)
 Environment-10-50°C,<90%
Operating amb. Temp. & Hum  -10-50°C,<90% no condensation
 Noise (1m)<70dB
 Refrigeration mode Forced air cooling
size / weight2010*1060*2000mm      1.5t2800*1200*2000mm       2.5t4000*1200*2000mm       4t

 

Specifications

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Customization:’, ‘Available’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Nature of Source Flow:’, ‘Active Inverter’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Certification:’, ‘ISO9001, CE’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Generatorxa0powerxa0converter’, ‘DMGC300K’, ‘DMGC500K’, ‘DMGC1000K’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Generator rated power’, ‘300KW’, ‘500KW’, ‘1000KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated voltage of generator (AC)’, ‘400V/690V’, ‘400V/690V’, ‘400V/690V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input voltage range (AC)’, ‘0-550V/0-800V’, ‘0-550V/0-800V’, ‘0-550V/0-800V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated output powerxa0(AC)’, ‘300KW’, ‘500KW’, ‘1000KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘MPPT MPPT Voltage rangexa0(AC)’, ‘250-500V/400-750V’, ‘250-500V/400-750V’, ‘250-500V/400-750V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. Input currentxa0(AC)’, ‘476A/276A’, ‘794A/460A’, ‘1588A/920A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated output currentxa0(AC)’, ‘433A/251A’, ‘722A/418A’, ‘1444A/837A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THDxa0Current harmonic’, ‘<3%(At rated power)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘>0.99’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. efficiency’, ‘96%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Electrical structure’, ‘Power frequency transformer’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Allowable grid voltage range (AC)’, ‘220V/380V/440V/480Vxa0(Three-phase) ±20%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Allowable grid frequency range’, ’50Hz/60Hz±10%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic operation conditions’, ‘AC input and power grid meet the requirements, and the power converter operates automatically’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Restart time after power failure’, ‘2min (xa0Adjustable)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Function’, ‘Rectification, wind turbine curve setting,xa0adjustable output power’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic protection’, ‘Reverse connection protection, short circuit protection, island effect protection,xa0LVRT,xa0overheat protection, overload protection, ground fault protection, lightning arrester,xa0etc’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display’, ‘Touch screen’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Monitoring content’, ‘Generatorxa0voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection level’, ‘IP20(Indoor)IP65 (Outdoors)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Telematics’, ‘RS485/USB/GPRS/WIFI/Ethernet (Optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Environment’, ‘-10-50°C,<90%Operating amb. Temp. & Hum xa0-10-50°C,<90% no condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘<70dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Refrigeration mode’, ‘Forced air cooling’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘ size / weight’, ‘2010*1060*2000mmxa0xa0xa0xa0xa0xa01.5t’, ‘2800*1200*2000mmxa0xa0xa0xa0xa0xa0xa02.5t’, ‘4000*1200*2000mmxa0xa0xa0xa0xa0xa0xa04t’]

Key Features

  • Manufacturer/Factory & Trading Company: Manufacturer/Factory & Trading Company