Split Phase Inverter with Two Phase Output AC110V/220V AC120V/240V 30kw 50kw Pure Sine Wave off Grid Power Inverter DC to AC Power Inverters
- Strona główna
- Split Phase Inverter with Two Phase Output AC110V/220V AC120V/240V 30kw 50kw Pure Sine Wave off Grid Power Inverter DC to AC Power Inverters
Przegląd projektów










Opis produktu
Power Frequency Pure Sine Wave Inverter Features:
1.Complete isolation-type inverter technology, noiseless output.
2.Adoption of advanced SPWM technology, pure sine wave output.
3.Dynamic current loop control technology to ensure inverter reliable operation.
4.Wide DC input voltage range.
5.Excellent EMC design.
6.Low output harmonic distortion (THD≤3%).
7.LED indicators for input voltage range, load power range, normal output & failure state.
8.Optional energy saving mode.
9.Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage, over-temperature, and inverter’s inner fault identification protections.
Application
1. For desolate area like mountain, island, pasturing area, etc.
2. For transportation system like beacon light, traffic light, street light, etc.
3. For communication system: unattached operation microwave middle station, optical
cable maintenance station, etc.
4. For photovoltaic power station, wind-solar power station, park charging station, family
power house, factory power station, etc.
5. For solar building: has good business future.
6. For the new technology application project.
off grid solar power system
off grid wind turbine power system
50KW off grid two phase inverter technical parameters
| Model | NB220-50KTZ |
| Pojemność znamionowa | Wyjście dwufazowe 50 kW |
| Tryb obwodu | IGBT/PWM |
| DC Input | |
| Wejściowy prąd znamionowy | DC220V |
| Zakres napięcia wejściowego DC | DC180-270V |
| Wejściowy prąd znamionowy | 252.5A |
| AC Output | |
| Tryb wyjścia | Dwa przewody trójfazowe |
| Fala wyjściowa | Czysta fala sinusoidalna |
| Napięcie wyjściowe | L1-N: 120Vac, L2-N: 120Vac, L1-L2: 240Vac |
| Dokładność napięcia wyjściowego | ±1% |
| Częstotliwość wyjściowa | 50Hz/60HZ |
| Dokładność częstotliwości wyjściowej | ±0.01% |
| Moc znamionowa wyjścia | 50KW |
| Wyjście Prąd znamionowy | 227.2A |
| Współczynnik mocy | 1 |
| Przeciążalność | 120% 10 minutes |
| Wydajność nadprądowa | 200% 10 seconds |
| Dynamiczny zakres napięcia przejściowego | 2% (zmiana obciążenia 0~100%) |
| VTHD(Zniekształcenie) | THD<3%( non-linear load) |
| Tryb wyświetlania | |
| Okno wyświetlacza | Touch screen display |
| Czterocyfrowy woltomierz | Dokładność 0,1 V |
| Czterocyfrowy amperomierz | Dokładność 0,1 A |
| Czterocyfrowy miernik częstotliwości | Dokładność 0,1 Hz |
| Czterocyfrowy miernik mocy/współczynnika mocy | Dokładność 0,1 W |
| System | |
| Wydajność systemu | Tryb normalny: 94% |
| insulation resistance | DC> 500V 20MΩ |
| wytrzymałość izolacyjna | (Input and output to ground)1800Vdc, leakage current<3.5mA, No-arcing for 1 min |
| Klasa ochrony | IP22 |
| Metoda okablowania | Zaciski okablowania wejściowego i wyjściowego, bank linii |
| Metody termiczne | Wymuszone chłodzenie wentylatorem transformatora |
| Temperatura robocza | -10ºC~+50ºC |
| Wilgotność względna | 0-90% (bez kondensacji) |
| Hałas (dB) | <65dB |
| Funkcja ochrony | Zabezpieczenie przed cofnięciem sygnału wejściowego, zabezpieczenie przed zbyt niskim napięciem wejściowym, zabezpieczenie przed przeciążeniem wyjścia, zabezpieczenie przed zwarciem wyjścia, zabezpieczenie termiczne |
| Wyposażony w AC Bypass | Tak |
| Interfejs komunikacyjny | RS485/WIFI/GPRS/Ethernet (optional) |
| Rozmiar produktu (dł. * szer. * wys.) mm | 760×760×1520 |
| Waga produktu (kg) | 450 kg |
20KW off grid two phase inverter technical parameters
| Model | NB220-20KSZ | NB110-20KSZ | NB96-20KSZ | NB48-20KSZ |
| Pojemność znamionowa | Wyjście dwufazowe 20 kW | |||
| Tryb obwodu | IGBT/PWM | |||
| DC Input | ||||
| Wejściowy prąd znamionowy | DC220V | DC110V | DC96V | DC48V |
| Zakres napięcia wejściowego DC | DC180-300V | DC80-145V | DC75V-135V | DCC40V-60V |
| Wejściowy prąd znamionowy | 92.6A | 185A | 208.3A | 416.7A |
| AC Output | ||||
| Tryb wyjścia | Dwa przewody trójfazowe | |||
| Fala wyjściowa | Czysta fala sinusoidalna | |||
| Napięcie wyjściowe | L1-N: 110Vac, L2-N: 110Vac, L1-L2: 220Vac | |||
| Dokładność napięcia wyjściowego | ±1% | |||
| Częstotliwość wyjściowa | 50Hz | |||
| Dokładność częstotliwości wyjściowej | ±0.01% | |||
| Pojemność znamionowa | 25KVA | |||
| Moc znamionowa wyjścia | 20KW | |||
| Wyjście Amper znamionowy | 90.9A | |||
| Maksymalne przekroczenie prądu wyjściowego | 136.4A | |||
| Maksymalny prąd znamionowy obciążenia | 90.9A | |||
| Współczynnik mocy | 0.8 | |||
| Przeciążalność | 120% 109A, 3 minuty, 150% 136.4A, 10 sekund | |||
| Dynamiczny zakres napięcia przejściowego | 2% (zmiana obciążenia 0~100%) | |||
| VTHD(Zniekształcenie) | THD<3%( non-linear load) | |||
| Tryb wyświetlania | ||||
| Okno wyświetlacza | Wyświetlacz LED cztery w jednym o wysokiej dokładności | |||
| Czterocyfrowy woltomierz | Dokładność 0,1 V | |||
| Czterocyfrowy amperomierz | Dokładność 0,1 A | |||
| Czterocyfrowy miernik częstotliwości | Dokładność 0,1 Hz | |||
| Czterocyfrowy miernik mocy/współczynnika mocy | Dokładność 0,1 W | |||
| System | ||||
| Wydajność systemu | Tryb normalny: 94% | |||
| insulation resistance | DC> 500V 20MΩ | |||
| wytrzymałość izolacyjna | (Input and output to ground)1800Vdc, leakage current<3.5mA, No-arcing for 1 min |
|||
| Klasa ochrony | IP22 | |||
|
th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Nature of Source Flow:’, ‘Passive inverter’] th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Certyfikacja:’, ‘ISO9001, RoHS, CE’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated Capacity’, ‘Output two phase 50KW’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Circuit Mode’, ‘IGBT/PWM’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘DC220V’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage Range’, ‘DC180-270V’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘252.5A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Mode’, ‘Two phase three wires’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Wave’, ‘Pure Sine Wave’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage’, ‘L1-N: 120Vac,xa0 L2-N: 120Vac,xa0 L1-L2: 240Vac’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage accuracy’, ‘±1%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency’, ’50Hz/60HZ’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ‘±0.01%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated power’, ’50KW’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Rated current’, ‘227.2A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘1’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%xa0 10 minutes’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%xa0 10 seconds’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Dynamic voltage transient range’, ‘2%(0~100% load change)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘VTHD(Distortion)’, ‘THD<3%( non-linear load)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display Window’, ‘Touch screen display’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit voltmeter’, ‘Accuracy 0.1V’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit ampere meter’, ‘Accuracy 0.1A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit frequency meter’, ‘Accuracy 0.1Hz’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit power/power factor meter’, ‘Accuracy 0.1W’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘System efficiency’, ‘Normal mode: 94%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulationxa0resistance’, ‘DC> 500V 20MΩ’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulating strength’, ‘(Input and output to ground)1800Vdc, leakage current<3.5mA,No-arcing for 1 min’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Class’, ‘IP22’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wiring method’, ‘Input and output wiring terminals,line bank’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Thermal methods’, ‘Transformer forced fan cooling’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working temperature’, ‘-10ºC~+50ºC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Relative humidity’, ‘0-90%(No condensation)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise(dB)’, ‘<65dB’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Equipped with AC Bypass’, ‘Yes’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Product Size(L*W*H)mm’, ‘760×760×1520’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Product Weight(kg)’, ‘450kg’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated Capacity’, ‘Output two phase 20KW’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Circuit Mode’, ‘IGBT/PWM’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘DC220V’, ‘DC110V’, ‘DC96V’, ‘DC48V’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage Range’, ‘DC180-300V’, ‘DC80-145V’, ‘DC75V-135V’, ‘DCC40V-60V’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘92.6A’, ‘185A’, ‘208.3A’, ‘416.7A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Mode’, ‘Two phase three wires’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Wave’, ‘Pure Sine Wave’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage’, ‘L1-N: 110Vac,xa0 L2-N: 110Vac,xa0 L1-L2: 220Vac’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage accuracy’, ‘±1%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency’, ’50Hz’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ‘±0.01%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated capacity’, ’25KVA’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated power’, ’20KW’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Rated ampere’, ‘90.9A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Maximum output over current’, ‘136.4A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Maximum nominal current of loads’, ‘90.9A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘0.8’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120% 109A ,3 minutes,150% 136.4A,10 seconds’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Dynamic voltage transient range’, ‘2%(0~100% load change)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘VTHD(Distortion)’, ‘THD<3%( non-linear load)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display Window’, ‘High accuracy four-in-one LED display’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit voltmeter’, ‘Accuracy 0.1V’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit ampere meter’, ‘Accuracy 0.1A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit frequency meter’, ‘Accuracy 0.1Hz’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit power/power factor meter’, ‘Accuracy 0.1W’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘System efficiency’, ‘Normal mode: 94%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulationxa0resistance’, ‘DC> 500V 20MΩ’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulating strength’, ‘(Input and output to ground)1800Vdc, leakage current<3.5mA,No-arcing for 1 min’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Class’, ‘IP22’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wiring method’, ‘Input and output wiring terminals,line bank’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Thermal methods’, ‘Transformer forced fan cooling’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working temperature’, ‘-10ºC~+50ºC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Relative humidity’, ‘0-90%(No condensation)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise(dB)’, ‘<65dB’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Equipped with AC Bypass’, ‘Yes’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Product Size/Weight(L*W*H)mm’, ‘550*480*950mm/135kg’] |
||||
Kluczowe cechy
- Producent/fabryka i firma handlowa: Producent/fabryka i firma handlowa