Split Phase Inverter with Two Phase Output AC110V/220V AC120V/240V 30kw 50kw Pure Sine Wave off Grid Power Inverter DC to AC Power Inverters

Split Phase Inverter with Two Phase Output AC110V/220V AC120V/240V 30kw 50kw Pure Sine Wave off Grid Power Inverter DC to AC Power Inverters

Energy Producers Ltd
Kategorie:
2026-04-05

Przegląd projektów

Podobała Ci się ta praca? Podziel się

Opis produktu

Opis produktu

Power Frequency Pure Sine Wave Inverter Features:

1.Complete isolation-type inverter technology, noiseless output.

2.Adoption of advanced SPWM technology, pure sine wave output.

3.Dynamic current loop control technology to ensure inverter reliable operation.

4.Wide DC input voltage range.

5.Excellent EMC design.

6.Low output harmonic distortion (THD≤3%).

7.LED indicators for input voltage range, load power range, normal output & failure state.

8.Optional energy saving mode.

9.Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage, over-temperature, and inverter’s inner fault identification protections.

10.Wide working temperature range (industrial level).
11.Continuous operation at full power.
Application
1. For desolate area like mountain, island, pasturing area, etc.
2. For transportation system like beacon light, traffic light, street light, etc.
3. For communication system: unattached operation microwave middle   station, optical
cable maintenance station, etc.
4. For photovoltaic power station, wind-solar power station, park charging station, family
   power house, factory power station, etc.
5. For solar building: has good business future.
6. For the new technology application project.


                                                                  
off grid solar power system
 

                                                              off grid wind turbine power system 

Szczegółowe zdjęcia

Parametry produktu

 

50KW off grid two phase inverter technical parameters

Model NB220-50KTZ
Pojemność znamionowa Wyjście dwufazowe 50 kW
Tryb obwodu IGBT/PWM
DC Input
Wejściowy prąd znamionowy DC220V
Zakres napięcia wejściowego DC DC180-270V
Wejściowy prąd znamionowy 252.5A
AC Output
Tryb wyjścia Dwa przewody trójfazowe
Fala wyjściowa Czysta fala sinusoidalna
Napięcie wyjściowe L1-N: 120Vac,  L2-N: 120Vac,  L1-L2: 240Vac
Dokładność napięcia wyjściowego ±1%
Częstotliwość wyjściowa 50Hz/60HZ
Dokładność częstotliwości wyjściowej ±0.01%
Moc znamionowa wyjścia 50KW
Wyjście Prąd znamionowy 227.2A
Współczynnik mocy 1
Przeciążalność 120%  10 minutes
Wydajność nadprądowa 200%  10 seconds
Dynamiczny zakres napięcia przejściowego 2% (zmiana obciążenia 0~100%)
VTHD(Zniekształcenie) THD<3%( non-linear load)
Tryb wyświetlania
Okno wyświetlacza Touch screen display
Czterocyfrowy woltomierz Dokładność 0,1 V
Czterocyfrowy amperomierz Dokładność 0,1 A
Czterocyfrowy miernik częstotliwości Dokładność 0,1 Hz
Czterocyfrowy miernik mocy/współczynnika mocy Dokładność 0,1 W
System
Wydajność systemu Tryb normalny: 94%
insulation resistance DC> 500V 20MΩ
wytrzymałość izolacyjna (Input and output to ground)1800Vdc, leakage current<3.5mA,
No-arcing for 1 min
Klasa ochrony IP22
Metoda okablowania Zaciski okablowania wejściowego i wyjściowego, bank linii
Metody termiczne Wymuszone chłodzenie wentylatorem transformatora
 Temperatura robocza -10ºC~+50ºC
 Wilgotność względna 0-90% (bez kondensacji)
Hałas (dB) <65dB
Funkcja ochrony Zabezpieczenie przed cofnięciem sygnału wejściowego, zabezpieczenie przed zbyt niskim napięciem wejściowym, zabezpieczenie przed przeciążeniem wyjścia, zabezpieczenie przed zwarciem wyjścia, zabezpieczenie termiczne
Wyposażony w AC Bypass Tak
Interfejs komunikacyjny RS485/WIFI/GPRS/Ethernet (optional)
Rozmiar produktu (dł. * szer. * wys.) mm 760×760×1520
Waga produktu (kg) 450 kg

20KW off grid two phase inverter technical parameters

th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Customization:’, ‘Available’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Nature of Source Flow:’, ‘Passive inverter’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Certyfikacja:’, ‘ISO9001, RoHS, CE’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Model’, ‘NB220-50KTZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated Capacity’, ‘Output two phase 50KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Circuit Mode’, ‘IGBT/PWM’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘DC220V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage Range’, ‘DC180-270V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘252.5A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Mode’, ‘Two phase three wires’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Wave’, ‘Pure Sine Wave’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage’, ‘L1-N: 120Vac,xa0 L2-N: 120Vac,xa0 L1-L2: 240Vac’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage accuracy’, ‘±1%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency’, ’50Hz/60HZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ‘±0.01%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated power’, ’50KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Rated current’, ‘227.2A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%xa0 10 minutes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%xa0 10 seconds’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Dynamic voltage transient range’, ‘2%(0~100% load change)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘VTHD(Distortion)’, ‘THD<3%( non-linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display Window’, ‘Touch screen display’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit voltmeter’, ‘Accuracy 0.1V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit ampere meter’, ‘Accuracy 0.1A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit frequency meter’, ‘Accuracy 0.1Hz’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit power/power factor meter’, ‘Accuracy 0.1W’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘System efficiency’, ‘Normal mode: 94%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulationxa0resistance’, ‘DC> 500V 20MΩ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulating strength’, ‘(Input and output to ground)1800Vdc, leakage current<3.5mA,No-arcing for 1 min’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Class’, ‘IP22’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wiring method’, ‘Input and output wiring terminals,line bank’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Thermal methods’, ‘Transformer forced fan cooling’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working temperature’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Relative humidity’, ‘0-90%(No condensation)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise(dB)’, ‘<65dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Equipped with AC Bypass’, ‘Yes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Product Size(L*W*H)mm’, ‘760×760×1520’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Product Weight(kg)’, ‘450kg’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Model’, ‘NB220-20KSZ’, ‘NB110-20KSZ’, ‘NB96-20KSZ’, ‘NB48-20KSZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated Capacity’, ‘Output two phase 20KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Circuit Mode’, ‘IGBT/PWM’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘DC220V’, ‘DC110V’, ‘DC96V’, ‘DC48V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage Range’, ‘DC180-300V’, ‘DC80-145V’, ‘DC75V-135V’, ‘DCC40V-60V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘92.6A’, ‘185A’, ‘208.3A’, ‘416.7A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Mode’, ‘Two phase three wires’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Wave’, ‘Pure Sine Wave’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage’, ‘L1-N: 110Vac,xa0 L2-N: 110Vac,xa0 L1-L2: 220Vac’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage accuracy’, ‘±1%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency’, ’50Hz’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ‘±0.01%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated capacity’, ’25KVA’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated power’, ’20KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Rated ampere’, ‘90.9A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Maximum output over current’, ‘136.4A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Maximum nominal current of loads’, ‘90.9A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘0.8’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120% 109A ,3 minutes,150% 136.4A,10 seconds’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Dynamic voltage transient range’, ‘2%(0~100% load change)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘VTHD(Distortion)’, ‘THD<3%( non-linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display Window’, ‘High accuracy four-in-one LED display’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit voltmeter’, ‘Accuracy 0.1V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit ampere meter’, ‘Accuracy 0.1A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit frequency meter’, ‘Accuracy 0.1Hz’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit power/power factor meter’, ‘Accuracy 0.1W’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘System efficiency’, ‘Normal mode: 94%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulationxa0resistance’, ‘DC> 500V 20MΩ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulating strength’, ‘(Input and output to ground)1800Vdc, leakage current<3.5mA,No-arcing for 1 min’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Class’, ‘IP22’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wiring method’, ‘Input and output wiring terminals,line bank’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Thermal methods’, ‘Transformer forced fan cooling’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working temperature’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Relative humidity’, ‘0-90%(No condensation)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise(dB)’, ‘<65dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Equipped with AC Bypass’, ‘Yes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Product Size/Weight(L*W*H)mm’, ‘550*480*950mm/135kg’]

Model NB220-20KSZ NB110-20KSZ NB96-20KSZ NB48-20KSZ
Pojemność znamionowa Wyjście dwufazowe 20 kW
Tryb obwodu IGBT/PWM
DC Input
Wejściowy prąd znamionowy DC220V DC110V DC96V DC48V
Zakres napięcia wejściowego DC DC180-300V DC80-145V DC75V-135V DCC40V-60V
Wejściowy prąd znamionowy 92.6A 185A 208.3A 416.7A
AC Output
Tryb wyjścia Dwa przewody trójfazowe
Fala wyjściowa Czysta fala sinusoidalna
Napięcie wyjściowe L1-N: 110Vac,  L2-N: 110Vac,  L1-L2: 220Vac
Dokładność napięcia wyjściowego ±1%
Częstotliwość wyjściowa 50Hz
Dokładność częstotliwości wyjściowej ±0.01%
Pojemność znamionowa 25KVA
Moc znamionowa wyjścia 20KW
Wyjście Amper znamionowy 90.9A
Maksymalne przekroczenie prądu wyjściowego 136.4A
Maksymalny prąd znamionowy obciążenia 90.9A
Współczynnik mocy 0.8
Przeciążalność 120% 109A, 3 minuty, 150% 136.4A, 10 sekund
Dynamiczny zakres napięcia przejściowego 2% (zmiana obciążenia 0~100%)
VTHD(Zniekształcenie) THD<3%( non-linear load)
Tryb wyświetlania
Okno wyświetlacza Wyświetlacz LED cztery w jednym o wysokiej dokładności
Czterocyfrowy woltomierz Dokładność 0,1 V
Czterocyfrowy amperomierz Dokładność 0,1 A
Czterocyfrowy miernik częstotliwości Dokładność 0,1 Hz
Czterocyfrowy miernik mocy/współczynnika mocy Dokładność 0,1 W
System
Wydajność systemu Tryb normalny: 94%
insulation resistance DC> 500V 20MΩ
wytrzymałość izolacyjna (Input and output to ground)1800Vdc, leakage current<3.5mA,
No-arcing for 1 min
Klasa ochrony IP22

Kluczowe cechy

  • Producent/fabryka i firma handlowa: Producent/fabryka i firma handlowa