Split Phase Inverter with Two Phase Output AC110V/220V AC120V/240V 30kw 50kw Pure Sine Wave off Grid Power Inverter DC to AC Power Inverters

Split Phase Inverter with Two Phase Output AC110V/220V AC120V/240V 30kw 50kw Pure Sine Wave off Grid Power Inverter DC to AC Power Inverters

شركة منتجو الطاقة المحدودة
الفئات:
2026-04-05

نظرة عامة على المشاريع

هل أعجبك هذا العمل؟ يرجى المشاركة

وصف المنتج

وصف المنتج

Power Frequency Pure Sine Wave Inverter Features:

1.Complete isolation-type inverter technology, noiseless output.

2.Adoption of advanced SPWM technology, pure sine wave output.

3.Dynamic current loop control technology to ensure inverter reliable operation.

4.Wide DC input voltage range.

5.Excellent EMC design.

6.Low output harmonic distortion (THD≤3%).

7.LED indicators for input voltage range, load power range, normal output & failure state.

8.Optional energy saving mode.

9.Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage, over-temperature, and inverter’s inner fault identification protections.

10.Wide working temperature range (industrial level).
11.Continuous operation at full power.
Application
1. For desolate area like mountain, island, pasturing area, etc.
2. For transportation system like beacon light, traffic light, street light, etc.
3. For communication system: unattached operation microwave middle   station, optical
cable maintenance station, etc.
4. For photovoltaic power station, wind-solar power station, park charging station, family
   power house, factory power station, etc.
5. For solar building: has good business future.
6. For the new technology application project.


                                                                  
off grid solar power system
 

                                                              off grid wind turbine power system 

Detailed Photos

Product Parameters

 

50KW off grid two phase inverter technical parameters

الطراز NB220-50KTZ
Rated Capacity Output two phase 50KW
Circuit Mode IGBT/PWM
DC Input
Input Rated Current DC220V
Input DC voltage Range DC180-270V
Input Rated Current 252.5A
AC Output
Output Mode Two phase three wires
Output Wave موجة جيبية نقية
Output Voltage L1-N: 120Vac,  L2-N: 120Vac,  L1-L2: 240Vac
Output Voltage accuracy ±1%
Output frequency 50Hz/60HZ
Output frequency accuracy ±0.01%
Output rated power 50 كيلو وات
Output Rated current 227.2A
معامل القدرة 1
Overload capacity 120%  10 minutes
Overcurrent capacity 200%  10 seconds
Dynamic voltage transient range 2%(0~100% load change)
VTHD(Distortion) THD<3%( non-linear load)
Display Mode
Display Window Touch screen display
Four digit voltmeter Accuracy 0.1V
Four digit ampere meter Accuracy 0.1A
Four digit frequency meter Accuracy 0.1Hz
Four digit power/power factor meter Accuracy 0.1W
System
System efficiency Normal mode: 94%
insulation resistance DC> 500V 20MΩ
insulating strength (Input and output to ground)1800Vdc, leakage current<3.5mA,
No-arcing for 1 min
Protection Class IP22
Wiring method Input and output wiring terminals,line bank
Thermal methods Transformer forced fan cooling
 درجة حرارة العمل -10ºC~+50ºC
 الرطوبة النسبية 0-90%(No condensation)
Noise(dB) <65dB
Protection Function Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection
Equipped with AC Bypass نعم
Communication interface RS485/WIFI/GPRS/Ethernet (optional)
Product Size(L*W*H)mm 760×760×1520
Product Weight(kg) 450kg

20KW off grid two phase inverter technical parameters

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘التخصيص:’، ‘متاح’]</ث

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Nature of Source Flow:’, ‘Passive inverter’]</ث

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Certification:’, ‘ISO9001, RoHS, CE’]</ث

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Model’, ‘NB220-50KTZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated Capacity’, ‘Output two phase 50KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Circuit Mode’, ‘IGBT/PWM’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘DC220V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage Range’, ‘DC180-270V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘252.5A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Mode’, ‘Two phase three wires’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Wave’, ‘Pure Sine Wave’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage’, ‘L1-N: 120Vac,xa0 L2-N: 120Vac,xa0 L1-L2: 240Vac’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage accuracy’, ‘±1%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency’, ’50Hz/60HZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ‘±0.01%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated power’, ’50KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Rated current’, ‘227.2A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%xa0 10 minutes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%xa0 10 seconds’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Dynamic voltage transient range’, ‘2%(0~100% load change)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘VTHD(Distortion)’, ‘THD<3%( non-linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display Window’, ‘Touch screen display’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit voltmeter’, ‘Accuracy 0.1V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit ampere meter’, ‘Accuracy 0.1A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit frequency meter’, ‘Accuracy 0.1Hz’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit power/power factor meter’, ‘Accuracy 0.1W’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘System efficiency’, ‘Normal mode: 94%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulationxa0resistance’, ‘DC> 500V 20MΩ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulating strength’, ‘(Input and output to ground)1800Vdc, leakage current<3.5mA,No-arcing for 1 min’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Class’, ‘IP22’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wiring method’, ‘Input and output wiring terminals,line bank’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Thermal methods’, ‘Transformer forced fan cooling’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working temperature’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Relative humidity’, ‘0-90%(No condensation)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise(dB)’, ‘<65dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Equipped with AC Bypass’, ‘Yes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Product Size(L*W*H)mm’, ‘760×760×1520’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Product Weight(kg)’, ‘450kg’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Model’, ‘NB220-20KSZ’, ‘NB110-20KSZ’, ‘NB96-20KSZ’, ‘NB48-20KSZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated Capacity’, ‘Output two phase 20KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Circuit Mode’, ‘IGBT/PWM’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘DC220V’, ‘DC110V’, ‘DC96V’, ‘DC48V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage Range’, ‘DC180-300V’, ‘DC80-145V’, ‘DC75V-135V’, ‘DCC40V-60V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input Rated Current’, ‘92.6A’, ‘185A’, ‘208.3A’, ‘416.7A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Mode’, ‘Two phase three wires’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Wave’, ‘Pure Sine Wave’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage’, ‘L1-N: 110Vac,xa0 L2-N: 110Vac,xa0 L1-L2: 220Vac’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Voltage accuracy’, ‘±1%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency’, ’50Hz’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ‘±0.01%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated capacity’, ’25KVA’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated power’, ’20KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output Rated ampere’, ‘90.9A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Maximum output over current’, ‘136.4A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Maximum nominal current of loads’, ‘90.9A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘0.8’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120% 109A ,3 minutes,150% 136.4A,10 seconds’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Dynamic voltage transient range’, ‘2%(0~100% load change)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘VTHD(Distortion)’, ‘THD<3%( non-linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display Window’, ‘High accuracy four-in-one LED display’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit voltmeter’, ‘Accuracy 0.1V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit ampere meter’, ‘Accuracy 0.1A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit frequency meter’, ‘Accuracy 0.1Hz’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Four digit power/power factor meter’, ‘Accuracy 0.1W’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘System efficiency’, ‘Normal mode: 94%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulationxa0resistance’, ‘DC> 500V 20MΩ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘insulating strength’, ‘(Input and output to ground)1800Vdc, leakage current<3.5mA,No-arcing for 1 min’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Class’, ‘IP22’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wiring method’, ‘Input and output wiring terminals,line bank’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Thermal methods’, ‘Transformer forced fan cooling’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working temperature’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Relative humidity’, ‘0-90%(No condensation)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise(dB)’, ‘<65dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection Function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Equipped with AC Bypass’, ‘Yes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Product Size/Weight(L*W*H)mm’, ‘550*480*950mm/135kg’]

الطراز NB220-20KSZ NB110-20KSZ NB96-20KSZ NB48-20KSZ
Rated Capacity Output two phase 20KW
Circuit Mode IGBT/PWM
DC Input
Input Rated Current DC220V DC110V DC96V DC48V
Input DC voltage Range DC180-300V DC80-145V DC75V-135V DCC40V-60V
Input Rated Current 92.6A 185A 208.3A 416.7A
AC Output
Output Mode Two phase three wires
Output Wave موجة جيبية نقية
Output Voltage L1-N: 110Vac,  L2-N: 110Vac,  L1-L2: 220Vac
Output Voltage accuracy ±1%
Output frequency 50Hz
Output frequency accuracy ±0.01%
Rated capacity 25KVA
Output rated power 20 كيلو وات
Output Rated ampere 90.9A
Maximum output over current 136.4A
Maximum nominal current of loads 90.9A
معامل القدرة 0.8
Overload capacity 120% 109A ,3 minutes,150% 136.4A,10 seconds
Dynamic voltage transient range 2%(0~100% load change)
VTHD(Distortion) THD<3%( non-linear load)
Display Mode
Display Window High accuracy four-in-one LED display
Four digit voltmeter Accuracy 0.1V
Four digit ampere meter Accuracy 0.1A
Four digit frequency meter Accuracy 0.1Hz
Four digit power/power factor meter Accuracy 0.1W
System
System efficiency Normal mode: 94%
insulation resistance DC> 500V 20MΩ
insulating strength (Input and output to ground)1800Vdc, leakage current<3.5mA,
No-arcing for 1 min
Protection Class IP22

الميزات الرئيسية

  • الشركة المصنعة/المصنع والشركة التجارية: الشركة المصنعة/المصنع والشركة التجارية