th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Customization:’, ‘Available’]
th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Nature of Source Flow:’, ‘Active Inverter’]
th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Certification:’, ‘ISO9001, CE’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Model’, ‘DMWG-5KD’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rating capacity’, ‘5KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rating AC output power’, ‘5KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. AC output power’, ‘5.5KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Isolation’, ‘Low frequency transformer isolation’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Recommending wind turbine power’, ‘5KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. AC open circuit voltage’, ‘780VDC’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘MPPT range’, ‘180-780VDC’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. DC Input current’, ’25A’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DC connecting mode’, ‘In-line waterproof terminal’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. Efficiency’, ‘94%’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Euro efficiency’, ‘92%’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Allowing network voltage range (single phase)’, ‘180~265VAC’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Allowing network frequency range’, ’50HZ±2%&60HZ±2%’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Total current waveform distortion factor’, ‘<3%’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘≥0.99’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Internal power consumption an night’, ‘<10W’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Comm. interfaces’, ‘RS485/RS232’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘electrical insulating performance’, ‘1500Vac,1minute’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Using environment temperature’, ‘-25~+60ºC’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Using environment humidity’, ‘0~100%’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection’, ‘Input short voltage,over voltage,opposing connection,output over current,short circuit,over heat etc.’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Cooling method’, ‘Air cooling’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise’, ‘<40dB’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection class’, ‘IP20(indoor),IP65(outdoor)’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Width ×depth ×height(mm)’, ‘656*430*303mm’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight (kg)’, ’60’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Type’, ‘FKJ-GT-5KW’, ’10KW’, ’15KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wind turbine rated power’, ‘5KW’, ’10KW’, ’15KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wind turbine Max. power’, ’10KW’, ’20KW’, ’30KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display Mode’, ‘LED’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Function’, ‘Rectifier,charge, control’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display content’, ‘DC output voltage’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘PWM constant voltage’, ‘≥420dc’, ‘≥520dc’, ‘≥600dc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘wind turbine 3-phase dump load voltage’, ‘450±5Vdc’, ‘560±5Vdc’, ‘650±5Vdc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Time-lapse of the wind turbine 3-phase dump load’, ’12-20 min’, ’12-20 min’, ’12-20 min’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Low-voltage’, ‘≤200Vdc’, ‘≤200Vdc’, ‘≤200Vdc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘PWM dump load fuse’, ’20A’, ’32A’, ’40A’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Fuse of DC output’, ’20A’, ’40A’, ’50A’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Work environment temperature’, ‘-30-60°C’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Relative humidity’, ‘<90% No condensation’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘<40dB’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Degree of protection’, ‘IP20(Indoor)’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Cooling method’, ‘Forced air cooling’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘*Communication interface (optional)’, ‘RS485/USB/GPRS/Ethernet’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘*Temperature compensation (optional)’, ‘-4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size of the controller (mm)’, ‘560*430*320’, ‘650*470*320’, ‘650*470*320’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight of the controller’, ’20Kg’, ’25Kg’, ’25Kg’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size of the dump load (mm)’, ‘670*520*460’, ‘760*520*550’, ‘760*520*550’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight of the dump load’, ’28Kg’, ’38Kg’, ’38Kg’]