50kw DC220V aan AC220V AC230V Enige Fase Inverter met Zuivere de Machtsomschakelaar van de Sinusgolfoutput

50kw DC220V aan AC220V AC230V Enige Fase Inverter met Zuivere de Machtsomschakelaar van de Sinusgolfoutput

Energieproducenten Ltd
Categorieën:
2026-04-05

Overzicht projecten

Vond je dit werk leuk? Delen

Product Beschrijving

Product Beschrijving

Power Frequency Pure Sine Wave Inverter Features:

1.Complete isolation-type inverter technology, noiseless output.

2.Adoption of advanced SPWM technology, pure sine wave output.

3.Dynamic current loop control technology to ensure inverter reliable operation.

4.Wide DC input voltage range.

5.Excellent EMC design.

6.Low output harmonic distortion (THD≤3%).

7.LED indicators for input voltage range, load power range, normal output & failure state.

8.Optional energy saving mode.

9.Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage, over-temperature, and inverter’s inner fault identification protections.

10.Wide working temperature range (industrial level).
11.Continuous operation at full power.
Application
1. For desolate area like mountain, island, pasturing area, etc.
2. For transportation system like beacon light, traffic light, street light, etc.
3. For communication system: unattached operation microwave middle   station, optical
cable maintenance station, etc.
4. For photovoltaic power station, wind-solar power station, park charging station, family
   power house, factory power station, etc.
5. For solar building: has good business future.
6. For the new technology application project.


                                                                  
off grid solar power system
 

                                                              off grid wind turbine power system 

Gedetailleerde foto's

Productparameters

 

50KVA off grid single phase inverter technical parameters

Model NB220-50KDZ NB380-50KDZ
DC
 input
Nominale ingangsspanning 220 VDC 380 VDC
Ingangsstroom 252.5 A 146 A
Ingangsgelijkspanning die bereik toestaat 180-280 VDC 350-500VDC
AC input
(AC bypass)
Bereik ingangsspanning toestaan 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15%
Ingangsstroom 455A / 417A / 227A /208A
Bypass overdrachtstijd ≤100 ms (4ms optional)
AC-uitgang Nominaal vermogen 50KVA
Nominale uitgangsspanning en -frequentie 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz
Nominale uitgangsstroom 455A / 417A / 227A / 208A
Nauwkeurigheid uitgangsspanning 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2%
Nauwkeurigheid uitgangsfrequentie 50Hz / 60Hz ± 0.05%
Golf  Pure sine wave   (Isolation transformer)
THD. ≤3%(Linear load)
Overbelastingscapaciteit 120%,10 minutes
Overstroomcapaciteit 200%,10 seconden
Overbelastingscapaciteit 120%, 3 minuten, 150%, 10 seconden
Crestfactor (CF) 3:1
 Efficiëntie omvormer >92%
Werkomgeving Diëlektrische sterkte 1500VAC,1minute
Geluid (1m) ≤50dB
Omgevingstemperatuur -10ºC~+50ºC
 Vochtigheid 0~90%, Geen condensatie
 Hoogte <2000m
Higher than 2000m rated power should be reduced
Productiefunctie Ingangsspanningsbeveiliging, ingangsonderspanningsbeveiliging, uitgangsoverbelastingsbeveiliging, uitgangskortsluitingsbeveiliging, thermische beveiliging
Communicatie-interface RS485/WIFI/GPRS/Ethernet (optioneel)
Equipped With Copper Transformer Ja
Solar Charger Optioneel
AC-lader Optioneel
Generator Port Optioneel
Maat 660*1300*1600 mm
Gewicht 450 kg

30KVA off grid single phase inverter technical parameters

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” …>Specifications

Model NB110-30KDZ NB220-30KDZ NB380-30KDZ
DC
input
Nominale ingangsspanning 110 VDC 220 VDC 380 VDC
Ingangsstroom 303A 151.5 A 87.7A
Ingangsgelijkspanning die bereik toestaat 90- 140VDC 180-280 VDC 320-500VDC
AC input
(AC bypass)
Bereik ingangsspanning toestaan 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15%
Ingangsstroom 272A / 250A / 136 A /125A
Bypass overdrachtstijd ≤40 ms (4ms optional)
AC-uitgang Nominaal vermogen 30KVA
Nominale uitgangsspanning en -frequentie 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz
Nominale uitgangsstroom 272A / 250A / 136 A /125A
Nauwkeurigheid uitgangsspanning 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2%
Nauwkeurigheid uitgangsfrequentie 50Hz / 60Hz ± 0.05%
Golf Zuivere sinusgolf (Isolatietransformator)
THD. ≤3%(Linear load)
Vermogensfactor (PF) 0.8
Overbelastingscapaciteit 120%,10 minutes
Overstroomcapaciteit 200%,10 seconden
Crestfactor (CF) 3:1
Efficiëntie omvormer >92%
Werkomgeving Diëlektrische sterkte 1500VAC,1minute
Geluid (1m) ≤50dB
Omgevingstemperatuur -10ºC~+50ºC
Vochtigheid 0~90%, Geen condensatie
Hoogte <2000m
Higher than 2000m rated power should be reduced
Productiefunctie Ingangsspanningsbeveiliging, ingangsonderspanningsbeveiliging, uitgangsoverbelastingsbeveiliging, uitgangskortsluitingsbeveiliging, thermische beveiliging
Communicatie-interface RS485/WIFI/GPRS/Ethernet (optioneel)
Equipped With Copper Transformer Ja
Solar Charger Optioneel
AC-lader Optioneel
Generator Port
th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Aanpassing:’, ‘Beschikbaar’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Nature of Source Flow:’, ‘Passive inverter’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Certificering:’, ‘ISO9001, RoHS, CE’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Model’, ‘NB220-50KDZ’, ‘NB380-50KDZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DCxa0input’, ‘Input rated voltage’, ‘220 VDC’, ‘380 VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘252.5 A’, ‘146 A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage allowing range’, ‘180-280 VDC’, ‘350-500VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC input(AC bypass)’, ‘Allow input voltage range’, ‘110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘455A / 417A / 227A /208A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Bypass transfer time’, ‘≤100 ms (4ms optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC output’, ‘Rated capacity’, ’50KVA’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated voltage and frequency’, ‘110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated current’, ‘455A / 417A / 227A / 208A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage accuracy’, ‘110 VAC / 120 VAC / 220 VAC / 240 VAC± 2%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ’50Hz / 60Hz ± 0.05%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wave’, ‘Pure sine wavexa0xa0 (Isolation transformer)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD.’, ‘≤3%(Linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,10 minutes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%,10 seconds’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,3 minutes,150%,10 second’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Crest factor (CF)’, ‘3:1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter efficiency’, ‘>92%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working Environment’, ‘Dielectric strength’, ‘1500VAC,1minute’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘≤50dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Omgevingstemperatuur’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Humidity’, ‘0~90%, No condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude’, ‘<2000m Higherxa0thanxa02000m ratedxa0powerxa0shouldxa0bexa0reduced’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Production function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Equipped With Copper Transformer’, ‘Yes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Solar Charger’, ‘Optional’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC Charger’, ‘Optional’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Generator Port’, ‘Optional’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size’, ‘660*1300*1600 mm’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight’, ‘450 kg’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Model’, ‘NB110-30KDZ’, ‘NB220-30KDZ’, ‘NB380-30KDZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DCinput’, ‘Input rated voltage’, ‘110 VDC’, ‘220 VDC’, ‘380 VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘303A’, ‘151.5 A’, ‘87.7A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage allowing range’, ’90- 140VDC’, ‘180-280 VDC’, ‘320-500VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC input(AC bypass)’, ‘Allow input voltage range’, ‘110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘272A / 250A / 136 A /125A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Bypass transfer time’, ‘≤40 ms (4ms optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC output’, ‘Rated capacity’, ’30KVA’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated voltage and frequency’, ‘110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated current’, ‘272A / 250A / 136 A /125A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage accuracy’, ‘110 VAC / 120 VAC / 220 VAC / 240 VAC± 2%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ’50Hz / 60Hz ± 0.05%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wave’, ‘Pure sine wave (Isolation transformer)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD.’, ‘≤3%(Linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor (PF)’, ‘0.8’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,10 minutes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%,10 seconds’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Crest factor (CF)’, ‘3:1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter efficiency’, ‘>92%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working Environment’, ‘Dielectric strength’, ‘1500VAC,1minute’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘≤50dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Omgevingstemperatuur’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Humidity’, ‘0~90%, No condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude’, ‘<2000mHigherxa0thanxa02000m ratedxa0powerxa0shouldxa0bexa0reduced’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Production function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Equipped With Copper Transformer’, ‘Yes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Solar Charger’, ‘Optional’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC Charger’, ‘Optional’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Generator Port’, ‘Optional’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size’, ‘630*1000*1430 mm’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight’, ‘295 Kg’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Type’, ‘NB216-20KSZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DC input’, ‘Input rated voltage’, ‘216VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘102.9A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage allowing range’, ‘180-280VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC bypass’, ‘Allow input voltage range’, ‘380VAC± 15% VAC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘30.4A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Bypass transfer time’, ‘≤100ms(4ms optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC output’, ‘Rated capacity’, ’20KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated voltage and frequency’, ‘Three phase 380VAC,50Hz/60HZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated current’, ‘30.4A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage accuracy’, ‘380VAC ± 2%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ’50Hz ± 0.05%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wave’, ‘Pure sine wavexa0 (Isolation transformer)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD.’, ‘≤3%(Linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor (PF)’, ‘1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,10 minutes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%,10 seconds’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Crest factor (CF)’, ‘3:1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter efficiency’, ‘>92%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working Environment’, ‘Dielectric strength’, ‘1500VAC,1minute’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘≤50dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Omgevingstemperatuur’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Humidity’, ‘0~90%, No condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude’, ‘<2000m Higherxa0thanxa02000m ratedxa0powerxa0shouldxa0bexa0reduced’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Production function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ac charger’, ‘(optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Battery, City grid (generator) priority’, ‘(optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size’, ‘550×1050×1340mm’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight’, ‘220KG’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Type’, ‘NB384-50KSZ’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DC input’, ‘Input rated voltage’, ‘384VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘144.7A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage allowing range’, ‘320-480VDC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC bypass’, ‘Allow input voltage range’, ‘380VAC± 15% VAC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ’76A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Bypass transfer time’, ‘≤100ms(4ms optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC output’, ‘Output rated power’, ’50KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated voltage and frequency’, ‘Three phase 380VAC,50HZ(Three phase four wire)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated current’, ’76A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage accuracy’, ‘380VAC ± 2%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ’50Hz ± 0.05%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wave’, ‘Pure sine wavexa0 (Isolation transformer)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD.’, ‘≤3%(Linear load)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor (PF)’, ‘1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,10 minutes’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%,10 seconds’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Crest factor (CF)’, ‘3:1’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter efficiency’, ‘>92%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working Environment’, ‘Dielectric strength’, ‘1500VAC,1minute’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘≤50dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Omgevingstemperatuur’, ‘-10ºC~+50ºC’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Humidity’, ‘0~90%, No condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude’, ‘<2000m Higherxa0thanxa02000m ratedxa0powerxa0shouldxa0bexa0reduced’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Production function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ac charger’, ‘(optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Battery, City grid (generator) priority’, ‘(optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size’, ‘630*1310*1573mm’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight’, ‘430KG’]

Belangrijkste kenmerken

  • Fabrikant/Fabriek & Handelsmaatschappij: Fabrikant/Fabriek & Handelsmaatschappij