Power Frequency Pure Sine Wave Inverter Features:
1.Complete isolation-type inverter technology, noiseless output.
2.Adoption of advanced SPWM technology, pure sine wave output.
3.Dynamic current loop control technology to ensure inverter reliable operation.
4.Wide DC input voltage range.
5.Excellent EMC design.
6.Low output harmonic distortion (THD≤3%).
7.LED indicators for input voltage range, load power range, normal output & failure state.
8.Optional energy saving mode.
9.Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage, over-temperature, and inverter’s inner fault identification protections.
Application
1. For desolate area like mountain, island, pasturing area, etc.
2. For transportation system like beacon light, traffic light, street light, etc.
3. For communication system: unattached operation microwave middle station, optical
cable maintenance station, etc.
4. For photovoltaic power station, wind-solar power station, park charging station, family
power house, factory power station, etc.
5. For solar building: has good business future.
6. For the new technology application project.
off grid solar power system
off grid wind turbine power system
30KVA off grid single phase inverter technical parameters
| Model | NB110-30KDZ | NB220-30KDZ | NB380-30KDZ | |
| DC input |
Wejściowe napięcie znamionowe | 110 VDC | 220 VDC | 380 VDC |
| Wejściowy prąd znamionowy | 303A | 151.5 A | 87.7A | |
| Dopuszczalny zakres napięcia wejściowego DC | 90- 140VDC | 180-280 VDC | 320-500VDC | |
| AC input (AC bypass) |
Dozwolony zakres napięcia wejściowego | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | ||
| Wejściowy prąd znamionowy | 272A / 250A / 136 A /125A | |||
| Czas transferu obejścia | ≤40 ms (4ms optional) | |||
| Wyjście AC | Pojemność znamionowa | 30KVA | ||
| Wyjściowe napięcie znamionowe i częstotliwość | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
| Prąd znamionowy wyjścia | 272A / 250A / 136 A /125A | |||
| Dokładność napięcia wyjściowego | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | |||
| Dokładność częstotliwości wyjściowej | 50Hz / 60Hz ± 0.05% | |||
| Fala | Pure sine wave (Isolation transformer) | |||
| THD. | ≤3%(Linear load) | |||
| Współczynnik mocy (PF) | 0.8 | |||
| Przeciążalność | 120%, 10 minut | |||
| Wydajność nadprądowa | 200%,10 sekund | |||
| Współczynnik szczytu (CF) | 3:1 | |||
| Wydajność falownika | >92% | |||
| Środowisko pracy | Wytrzymałość dielektryczna | 1500VAC,1minute | ||
| Hałas (1 m) | ≤50dB | |||
| Temperatura otoczenia | -10ºC~+50ºC | |||
| Wilgotność | 0~90%, bez kondensacji | |||
| Wysokość | <2000m Higher than 2000m rated power should be reduced |
|||
| Funkcja produkcji | Zabezpieczenie przed cofnięciem sygnału wejściowego, zabezpieczenie przed zbyt niskim napięciem wejściowym, zabezpieczenie przed przeciążeniem wyjścia, zabezpieczenie przed zwarciem wyjścia, zabezpieczenie termiczne | |||
| Interfejs komunikacyjny | RS485/WIFI/GPRS/Ethernet (opcjonalnie) | |||
| Wyposażony w transformator miedziany | Tak | |||
| Ładowarka słoneczna | Opcjonalnie | |||
| Ładowarka sieciowa | Opcjonalnie | |||
| Port generatora | Opcjonalnie | |||
| Rozmiar | 630*1000*1430 mm | |||
| Waga | 295 Kg | |||
20KW off grid three phase inverter technical parameters
| Typ | NB216-20KSZ | |
| Wejście DC | Wejściowe napięcie znamionowe | 216VDC |
| Wejściowy prąd znamionowy | 102.9A | |
| Dopuszczalny zakres napięcia wejściowego DC | 180-280VDC | |
| Obejście AC | Dozwolony zakres napięcia wejściowego | 380VAC± 15% VAC |
| Wejściowy prąd znamionowy | 30.4A | |
| Czas transferu obejścia | ≤100ms(4ms optional) | |
| Wyjście AC | Pojemność znamionowa | 20KW |
| Wyjściowe napięcie znamionowe i częstotliwość | Three phase 380VAC,50Hz/60HZ | |
| Prąd znamionowy wyjścia | 30.4A | |
| Dokładność napięcia wyjściowego | 380VAC ± 2% | |
| Dokładność częstotliwości wyjściowej | 50Hz ± 0.05% | |
| Fala | Pure sine wave (Isolation transformer) | |
| THD. | ≤3%(Linear load) | |
| Współczynnik mocy (PF) | 1 | |
| Przeciążalność | 120%, 10 minut | |
| Wydajność nadprądowa | 200%,10 sekund | |
| Współczynnik szczytu (CF) | 3:1 | |
| Wydajność falownika | >92% | |
| Środowisko pracy | Wytrzymałość dielektryczna | 1500VAC,1minute |
| Hałas (1 m) | ≤50dB | |
| Temperatura otoczenia | -10ºC~+50ºC | |
| Wilgotność | 0~90%, bez kondensacji | |
| Wysokość | <2000m Higher than 2000m rated power should be reduced |
|
| Funkcja produkcji | Zabezpieczenie przed cofnięciem sygnału wejściowego, zabezpieczenie przed zbyt niskim napięciem wejściowym, zabezpieczenie przed przeciążeniem wyjścia, zabezpieczenie przed zwarciem wyjścia, zabezpieczenie termiczne | |
| Interfejs komunikacyjny | RS485/WIFI/GPRS/Ethernet (opcjonalnie) | |
| Ładowarka sieciowa | (opcjonalnie) | |
| Bateria, priorytet sieci miejskiej (generator) | (opcjonalnie) | |
| Rozmiar | 550×1050×1340mm | |
| Waga | 220KG | |
50KW off grid three phase inverter technical parameters
| Typ | NB384-50KSZ | |
| Wejście DC | Wejściowe napięcie znamionowe | 384VDC |
| Wejściowy prąd znamionowy | 144.7A | |
| Dopuszczalny zakres napięcia wejściowego DC | 320-480VDC | |
| Obejście AC | Dozwolony zakres napięcia wejściowego |
th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Nature of Source Flow:’, ‘Passive inverter’] th style=”border:1px solid #ccc;padding:10px;background:#f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Certyfikacja:’, ‘ISO9001, RoHS, CE’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DCinput’, ‘Input rated voltage’, ‘110 VDC’, ‘220 VDC’, ‘380 VDC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘303A’, ‘151.5 A’, ‘87.7A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage allowing range’, ’90- 140VDC’, ‘180-280 VDC’, ‘320-500VDC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC input(AC bypass)’, ‘Allow input voltage range’, ‘110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘272A / 250A / 136 A /125A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Bypass transfer time’, ‘≤40 ms (4ms optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC output’, ‘Rated capacity’, ’30KVA’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated voltage and frequency’, ‘110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated current’, ‘272A / 250A / 136 A /125A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage accuracy’, ‘110 VAC / 120 VAC / 220 VAC / 240 VAC± 2%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ’50Hz / 60Hz ± 0.05%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wave’, ‘Pure sine wave (Isolation transformer)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD.’, ‘≤3%(Linear load)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor (PF)’, ‘0.8’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,10 minutes’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%,10 seconds’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Crest factor (CF)’, ‘3:1’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter efficiency’, ‘>92%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working Environment’, ‘Dielectric strength’, ‘1500VAC,1minute’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘≤50dB’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ambient temperature’, ‘-10ºC~+50ºC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Humidity’, ‘0~90%, No condensation’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude’, ‘<2000mHigherxa0thanxa02000m ratedxa0powerxa0shouldxa0bexa0reduced’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Production function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Equipped With Copper Transformer’, ‘Yes’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Solar Charger’, ‘Optional’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC Charger’, ‘Optional’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Generator Port’, ‘Optional’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size’, ‘630*1000*1430 mm’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight’, ‘295 Kg’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DC input’, ‘Input rated voltage’, ‘216VDC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘102.9A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage allowing range’, ‘180-280VDC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC bypass’, ‘Allow input voltage range’, ‘380VAC± 15% VAC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘30.4A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Bypass transfer time’, ‘≤100ms(4ms optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC output’, ‘Rated capacity’, ’20KW’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated voltage and frequency’, ‘Three phase 380VAC,50Hz/60HZ’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated current’, ‘30.4A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage accuracy’, ‘380VAC ± 2%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ’50Hz ± 0.05%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wave’, ‘Pure sine wavexa0 (Isolation transformer)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD.’, ‘≤3%(Linear load)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor (PF)’, ‘1’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,10 minutes’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%,10 seconds’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Crest factor (CF)’, ‘3:1’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter efficiency’, ‘>92%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working Environment’, ‘Dielectric strength’, ‘1500VAC,1minute’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘≤50dB’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ambient temperature’, ‘-10ºC~+50ºC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Humidity’, ‘0~90%, No condensation’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude’, ‘<2000m Higherxa0thanxa02000m ratedxa0powerxa0shouldxa0bexa0reduced’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Production function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ac charger’, ‘(optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Battery, City grid (generator) priority’, ‘(optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size’, ‘550×1050×1340mm’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight’, ‘220KG’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘DC input’, ‘Input rated voltage’, ‘384VDC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ‘144.7A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input DC voltage allowing range’, ‘320-480VDC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC bypass’, ‘Allow input voltage range’, ‘380VAC± 15% VAC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input rated current’, ’76A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Bypass transfer time’, ‘≤100ms(4ms optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘AC output’, ‘Output rated power’, ’50KW’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated voltage and frequency’, ‘Three phase 380VAC,50HZ(Three phase four wire)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rated current’, ’76A’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output voltage accuracy’, ‘380VAC ± 2%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output frequency accuracy’, ’50Hz ± 0.05%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wave’, ‘Pure sine wavexa0 (Isolation transformer)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD.’, ‘≤3%(Linear load)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor (PF)’, ‘1’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overload capacity’, ‘120%,10 minutes’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Overcurrent capacity’, ‘200%,10 seconds’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Crest factor (CF)’, ‘3:1’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Inverter efficiency’, ‘>92%’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Working Environment’, ‘Dielectric strength’, ‘1500VAC,1minute’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘≤50dB’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ambient temperature’, ‘-10ºC~+50ºC’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Humidity’, ‘0~90%, No condensation’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude’, ‘<2000m Higherxa0thanxa02000m ratedxa0powerxa0shouldxa0bexa0reduced’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Production function’, ‘Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communication interface’, ‘RS485/WIFI/GPRS/Ethernet (optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Ac charger’, ‘(optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Battery, City grid (generator) priority’, ‘(optional)’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size’, ‘630*1310*1573mm’] td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight’, ‘430KG’] |
Kluczowe cechy
- Producent/fabryka i firma handlowa: Producent/fabryka i firma handlowa