{"id":4182,"date":"2026-04-05T03:22:33","date_gmt":"2026-04-05T03:22:33","guid":{"rendered":"https:\/\/dminverter.com\/?post_type=product&#038;p=4182"},"modified":"2026-09-15T00:07:26","modified_gmt":"2026-09-15T00:07:26","slug":"all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw","status":"publish","type":"product","link":"https:\/\/dminverter.com\/nl\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/","title":{"rendered":"5\u201330 kW All in One on Grid Wind Turbine Controller and Grid-Tie Inverter with CE"},"content":{"rendered":"<div class=\"product-gallery\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_01-152.webp\" alt=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw 20kw 30kw\" width=\"550\" height=\"412\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_02-164.webp\" alt=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw 20kw 30kw\" width=\"550\" height=\"412\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_03-164.webp\" alt=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw 20kw 30kw\" width=\"550\" height=\"412\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_04-163.webp\" alt=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw 20kw 30kw\" width=\"550\" height=\"412\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_05-164.webp\" alt=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw 20kw 30kw\" width=\"550\" height=\"412\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_06-164.webp\" alt=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw 20kw 30kw\" width=\"550\" height=\"412\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_07-163.webp\" alt=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw 20kw 30kw\" width=\"550\" height=\"412\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_08-152.webp\" alt=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw 20kw 30kw\" width=\"550\" height=\"412\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_09-163.webp\" alt=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw 20kw 30kw\" width=\"550\" height=\"412\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_10-163.webp\" alt=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw 20kw 30kw\" width=\"550\" height=\"412\"><\/div>\n<p><span style=\"font-size:18px\"><span style=\"font-family:Arial, Helvetica, sans-serif\">Het netwindturbinesysteem bestaat uit een windturbine, een netcontroller, een netomvormer, een meetapparaat en een stroomdistributiesysteem. Windenergie wordt omgezet in AC elektrische energie door de windturbine, en dan omgezet in DC elektrische energie door het op net controlemechanisme, en dan wordt DC elektrische energie omgezet in AC elektrische energie van dezelfde frequentie en fase als het net door de op net omvormer, en een deel van de energie wordt geleverd aan de lokale belasting. Overtollige energie wordt aan het elektriciteitsnet geleverd.<\/span><br \/><span style=\"font-family:Arial, Helvetica, sans-serif\">Prestatiekenmerken van windturbineomvormers op het net<\/span><\/span><\/p>\n<p><span style=\"font-size:16px\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><b><span style=\"font-size:18px\"><span style=\"font-family:Arial, Helvetica, sans-serif\">On Grid Wind Turbine Controller<\/span><\/span><\/b><\/span><\/span><br \/><span style=\"font-size:18px\"><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">1. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">The product is manufactured according to the JB\/T6939.1-2004 industrial standard and GB\/T 19115.1-2003 national standard,and also with users&#8217; technical requirements.<\/span><\/span><\/span><\/span><br \/><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">2. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Big LCD Display. The graphics visually show&nbsp; the working status of controller.&nbsp; Abundant data display: real-time wind turbine voltage, current, power; dc output voltage, current, accumulative total generating electricity (The main-board is with battery, in the case of power off, history data can be stored for 30 days.) <\/span><\/span><\/span><\/span><br \/><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">3. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Two sets of control systems:PWM constant voltage system and three phase brake system.<\/span><\/span><\/span><\/span><br \/><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">4. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">PWM constant voltage control is 120% of the rated power of the wind turbine. In case exceeding of PWM&#8217;s capacity, the brake will automatically start immediately. After 10-20 minutes, the brake will stop and the wind turbine will re-start to resume power supply to ensure the safe running of overall wind turbine generation system.<\/span><\/span><\/span><\/span><br \/><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">5. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">When strong or super-strong wind, the controller can conduct DC constant voltage output to ensure the inverter safe running.<\/span><\/span><\/span><\/span><br \/><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">6.&nbsp;<\/span><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">When disconnected grid-connected inverter, the controller can conduct DC constant voltage output and wait for inverter resume to work. <\/span><\/span><\/span><\/span><br \/><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">7. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">When grid power is off, the inverter stops output to grid power, three-phase dump load of controller will automatically start, and wind turbine will be on braking status. When grid power resumes, the controller will stop three-phase dump load, wind turbine will resume to run, and inverter will resume to supply grid power.<\/span><\/span><\/span><\/span><br \/><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">8. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">The inside of controller is equipped with surge arrester. Limit instantaneous over voltage into wind generator within the controller or system bearable voltage range, or conduct the strong lightening current into earth to protect the equipment from lightning shock damage.<\/span><\/span><\/span><\/span><br \/><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">9. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">The controller is equipped with emergency stop switch; in case of emergency, press down the emergency stop button in the front panel to cut off all power supply of the controller and the wind turbine will immediately brake.(Please do not press this button in non-emergency situations.)<\/span><\/span><\/span><\/span><br \/><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">10. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">The controller is equipped with manual brake switch. when using this switch, the wind turbine will carry out brake forcibly.<\/span><\/span><\/span><\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">11. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\">Adopt Modbus communication protocol. It is convenient for customers to develop again.(optional)<\/span><\/span><br \/><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">12. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\">Ajust controller technical parameters, through RS485 interface. It is convenient for professional customers to adjust different wind turbines.(optional)<\/span><\/span><br \/><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">13. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\">Support WIFI and GPRS. Customer can monitor the working status of&nbsp; grid-tie wind power system in real time through PC or mobile terminal, or check&nbsp; historical working status. Mobile terminal is compatible with Android and IOS. (optional)<\/span><\/span><br \/><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">14. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\">Solar panel control system can be added according to customers&#8217; demand.(optional)<\/span><\/span><br \/><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"font-family:Arial, Helvetica, sans-serif\">15. <\/span><span style=\"font-family:Arial, Helvetica, sans-serif\">For different wind turbines type, the controller can be equipped with mechanical yawing, furled empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.(optional)<\/span><\/span><\/span><\/p>\n<p><span style=\"font-size:16px\"><span style=\"line-height:120%\"><span><span><span style=\"font-family:Arial, Helvetica, sans-serif\"><b><span style=\"font-size:18px\"><span style=\"line-height:120%\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">On Grid Wind Turbine Inverter<\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span style=\"font-size:18px\"><span style=\"font-family:Arial, Helvetica, sans-serif\">(1) Het hoofdcircuit gebruikt de DSP-chip geproduceerd door het Amerikaanse TI-bedrijf, de Duitse Infineon IGBT-module, de aandrijvingsbeveiliging is de Japanse Mitsubishi-beweging, en het uitgangsdeel op het net gebruikt de scheidingstransformator, die veilig en betrouwbaar is;&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\">(2) Met behulp van SPWM pulsbreedtemodulatie technologie, zuivere sinusgolf uitgang, automatische synchrone volgen met het net, power factor dicht bij 1, lage huidige harmonische inhoud, geen vervuiling van het net, geen impact;<\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\">(3) Ingang windturbine maximaal vermogen tracking technologie (MPPT)<\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\">(4) De vermogenscurve van de windturbine kan worden ingesteld, de standaardwaarde is 20 punten en de interne uitbreiding is 50<\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\">(5) 7-inch kleuren touchscreen display, systeembedrijfsgegevens en foutinformatie in een oogopslag, en handige parameterinstelling;<\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\">(6) Op netomvormer huidige closed-loop regeling, controleerbaar en instelbaar;<\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\">(7) Het bereik van de ingangsgelijkspanning is breed en kan worden aangepast aan de behoeften van verschillende gelegenheden;<\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\">(8) Detectietechnologie voor frequentiestoringen om anti-eilandregeling te realiseren;<\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\">(9) De uitgebreide vermogensbeschermingsregeling en de perfecte functies voor zelfdetectie en bescherming stoppen de omvormer op het elektriciteitsnet wanneer er een systeemstoring optreedt.<\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\">(10) Circuit structuur is compact, het maximale rendement\u226598%<\/span><\/p>\n<p><span style=\"font-family:Arial, Helvetica, sans-serif\">(11) Ondersteuning voor RS485, WiFi, GPRS, Ethernet en andere communicatiemethoden. U kunt de werkstatus van het opwekkingssysteem van de netwindenergie in realtime via de pc of mobiele telefoon controleren en u kunt ook de historische werkstatus opvragen. De mobiele terminal is compatibel met Android en IOS. Alle gegevens kunnen worden aangesloten op het internet der dingen.<\/span><\/span><\/p>\n<p><span style=\"font-size:20px\"><b>&nbsp; 20KW op netwindturbineregelaar en op netwindgeneratoromvormerparameters&nbsp;<\/b><\/span><\/p>\n<table border=\"1\" cellpadding=\"6\" cellspacing=\"0\" class=\"dm-clean-table\">\n<tbody>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><b><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:#3f3f3f\">Regelaar voor windturbines op het net<\/span><\/span><\/b><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><b><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">WGMC10K380<\/span><\/span><\/span><\/b><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">WGMC20K380<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:14px\"><span style=\"font-family:Calibri\"><span style=\"font-size:12px\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">WGMC30K380<\/span><\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><b><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:#3f3f3f\">Windturbine <\/span><\/span><\/b><b><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">i<\/span><\/span><\/b><b><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:#3f3f3f\">nput<\/span><\/span><\/b><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Stroom<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">10KW<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">20KW<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">30KW<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Max. Stuurvermogen\/-stroom<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">20KW\/40A<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">40KW\/80A<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">60KW\/120A<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Nominale spanning van windturbine (AC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">380V\/400V<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">380V\/400V<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">380V\/400V<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Bereik ingangsspanning<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">AC<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-600V<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-600V<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-600V<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">DC<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-900V<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-900V<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-900V<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Remspanning (DC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Standaard<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">550V\u00b11%<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">550V\u00b11%<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">550V\u00b11%<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Bereik instellen<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">530-560V<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">530-560V<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">530-560V<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Remstroom (DC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Standaard<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">30A<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">60A<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">90A<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Bereik instellen<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-30A<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-60A<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-90A<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Remtijd<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Standaard<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"4\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">10-20 min<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Bereik instellen<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"4\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-5000 min<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">*<\/span><\/span> <span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Overtoerenregeling generator<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Standaard <\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"4\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">&gt;300 tpm\/min<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Bereik instellen<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"4\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-1000 tpm\/min<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">* Controle over windsnelheid<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Standaard <\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"4\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">14 m\/s<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Bereik instellen<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"4\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-45 m\/s<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Handmatige bediening<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"5\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Handrem, *rem met afstandsbediening (met communicatiefunctie)<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Automatische controlefunctie<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"5\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Dump lastregeling, * gieren, * pitch, * mechanische rem, * hydraulische rem, <\/span><\/span><\/span><br \/><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">* elektromagnetische rem<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><b><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:#3f3f3f\">* PV. Ingang<\/span><\/span><\/b><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Nominaal vermogen (verhoogd)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">5KWp<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">5KWp<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">5KWp<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Werkspanning (DC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">550V \/ 660V<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">550V \/ 660V<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">550V \/ 660V<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><b><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:#3f3f3f\">DC-uitgangsparameters<\/span><\/span><\/b><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Bereik uitgangsspanning (DC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-550V<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-550V<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-550V<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Constante spanning (DC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Standaard<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">520V\u00b11%<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">520V\u00b11%<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">520V\u00b11%<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Bereik instellen<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">510-540V<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">510-540V<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">510-540V<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Constante stroom (DC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Standaard<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">24A <\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">48A<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">72A<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Bereik instellen<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-24A<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-48A<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-72A<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><b><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:#3f3f3f\">Omvormer voor windturbines op het net<\/span><\/span><\/b><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">DMWG10KTL<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">DMWG20KTL<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">DMWG30KTL<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Nominaal uitgangsvermogen (AC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">10KW<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">20KW<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">30KW<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Max. Uitgangsvermogen (AC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">11KW<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">22KW<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">33KW<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Bereik ingangsspanning (DC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-800V<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-800V<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">0-800V<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">MPPT Spanningsbereik (DC) (DC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">150V-700V<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">150V-700V<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">150V-700V<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Max. Ingangsstroom (DC)<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">2.4A<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">44.9A<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">67.3A<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Nominale stroom<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">20.4A<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"2\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">40.8A<\/span><\/span><\/span><\/span><\/td>\n<td><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">61.2A<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">THD Huidige harmonische <\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"4\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">&lt;3% (bij nominaal vermogen)<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Vermogensfactor<\/span><\/span><\/span><\/span><\/td>\n<td colspan=\"4\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">&gt;0.99<\/span><\/span><\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><span style=\"font-size:16px\"><span style=\"font-family:Calibri\"><span style=\"font-family:Arial, Helvetica, sans-serif\"><span style=\"color:black\">Max. effici\u00ebntie<\/span><\/span><\/span><\/span><\/td>\n<td>Specificaties<\/p>\n<table border=\"1\" cellpadding=\"8\" cellspacing=\"0\" class=\"dm-clean-table\">\n<tr style=\"background:#f5f5f5;font-weight:bold\">\n<th>Customization: Available<\/th>\n<th>Nature of Source Flow: Active Inverter<\/th>\n<th>Certification: ISO9001, RoHS, CE<\/th>\n<\/tr>\n<tr>\n<tr>\n<th>Regelaar voor windturbines op het net<\/th>\n<td>WGMC10K380<br \/>WGMC20K380<br \/>WGMC30K380<\/td>\n<\/tr>\n<tr>\n<th>Stroom<\/th>\n<td>10KW<br \/>20KW<br \/>30KW<\/td>\n<\/tr>\n<tr>\n<th>Max. Stuurvermogen\/-stroom<\/th>\n<td>20KW\/40A<br \/>40KW\/80A<br \/>60KW\/120A<\/td>\n<\/tr>\n<tr>\n<th>Nominale spanning van windturbine (AC)<\/th>\n<td>380V\/400V<br \/>380V\/400V<br \/>380V\/400V<\/td>\n<\/tr>\n<tr>\n<th>Bereik ingangsspanning<\/th>\n<td>AC<br \/>0-600V<br \/>0-600V<br \/>0-600V<\/td>\n<\/tr>\n<tr>\n<th>DC<\/th>\n<td>0-900V<br \/>0-900V<br \/>0-900V<\/td>\n<\/tr>\n<tr>\n<th>Remspanning (DC)<\/th>\n<td>Standaard<br \/>550V\u00b11%<br \/>550V\u00b11%<br \/>550V\u00b11%<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>530-560V<br \/>530-560V<br \/>530-560V<\/td>\n<\/tr>\n<tr>\n<th>Remstroom (DC)<\/th>\n<td>Standaard<br \/>30A<br \/>60A<br \/>90A<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>0-30A<br \/>0-60A<br \/>0-90A<\/td>\n<\/tr>\n<tr>\n<th>Remtijd<\/th>\n<td>Standaard<br \/>10-20 min<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>0-5000 min<\/td>\n<\/tr>\n<tr>\n<th>* Generator overspeed control<\/th>\n<td>Standaard<br \/>&gt;300 tpm\/min<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>0-1000 tpm\/min<\/td>\n<\/tr>\n<tr>\n<th>* Controle over windsnelheid<\/th>\n<td>Standaard<br \/>14 m\/s<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>0-45 m\/s<\/td>\n<\/tr>\n<tr>\n<th>Handmatige bediening<\/th>\n<td>Handrem, *rem met afstandsbediening (met communicatiefunctie)<\/td>\n<\/tr>\n<tr>\n<th>Automatische controlefunctie<\/th>\n<td>Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake<\/td>\n<\/tr>\n<tr>\n<th>Nominaal vermogen (verhoogd)<\/th>\n<td>5KWp<br \/>5KWp<br \/>5KWp<\/td>\n<\/tr>\n<tr>\n<th>Werkspanning (DC)<\/th>\n<td>550V \/ 660V<br \/>550V \/ 660V<br \/>550V \/ 660V<\/td>\n<\/tr>\n<tr>\n<th>Bereik uitgangsspanning (DC)<\/th>\n<td>0-550V<br \/>0-550V<br \/>0-550V<\/td>\n<\/tr>\n<tr>\n<th>Constante spanning (DC)<\/th>\n<td>Standaard<br \/>520V\u00b11%<br \/>520V\u00b11%<br \/>520V\u00b11%<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>510-540V<br \/>510-540V<br \/>510-540V<\/td>\n<\/tr>\n<tr>\n<th>Constante stroom (DC)<\/th>\n<td>Standaard<br \/>24A<br \/>48A<br \/>72A<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>0-24A<br \/>0-48A<br \/>0-72A<\/td>\n<\/tr>\n<tr>\n<th>Omvormer voor windturbines op het net<\/th>\n<td>DMWG10KTL<br \/>DMWG20KTL<br \/>DMWG30KTL<\/td>\n<\/tr>\n<tr>\n<th>Nominaal uitgangsvermogen (AC)<\/th>\n<td>10KW<br \/>20KW<br \/>30KW<\/td>\n<\/tr>\n<tr>\n<th>Max. Uitgangsvermogen (AC)<\/th>\n<td>11KW<br \/>22KW<br \/>33KW<\/td>\n<\/tr>\n<tr>\n<th>Bereik ingangsspanning (DC)<\/th>\n<td>0-800V<br \/>0-800V<br \/>0-800V<\/td>\n<\/tr>\n<tr>\n<th>MPPT Spanningsbereik (DC) (DC)<\/th>\n<td>150V-700V<br \/>150V-700V<br \/>150V-700V<\/td>\n<\/tr>\n<tr>\n<th>Max. Ingangsstroom (DC)<\/th>\n<td>2.4A<br \/>44.9A<br \/>67.3A<\/td>\n<\/tr>\n<tr>\n<th>Nominale stroom<\/th>\n<td>20.4A<br \/>40.8A<br \/>61.2A<\/td>\n<\/tr>\n<tr>\n<th>THD Huidige harmonische<\/th>\n<td>&lt;3% (bij nominaal vermogen)<\/td>\n<\/tr>\n<tr>\n<th>Vermogensfactor<\/th>\n<td>&gt;0.99<\/td>\n<\/tr>\n<tr>\n<th>Max. effici\u00ebntie<\/th>\n<td>98%<\/td>\n<\/tr>\n<tr>\n<th>Toelaatbaar bereik netspanning (AC)<\/th>\n<td>220V\/380V\/440V\/480V (Three-phase)\u00b120%<\/td>\n<\/tr>\n<tr>\n<th>Toelaatbaar netfrequentiebereik<\/th>\n<td>50Hz\/60Hz\u00b110%<\/td>\n<\/tr>\n<tr>\n<th>Automatische bedrijfsomstandigheden<\/th>\n<td>DC-ingang en elektriciteitsnet voldoen aan de vereisten en de omvormer werkt automatisch<\/td>\n<\/tr>\n<tr>\n<th>Opstarttijd na stroomuitval<\/th>\n<td>2min (instelbaar)<\/td>\n<\/tr>\n<tr>\n<th>Functie<\/th>\n<td>Gelijkrichting, DC-uitgang, uitgangsspanningsregeling, uitgangsstroomregeling, Dump Load-regeling, instelling regelparameters, instelling windturbinecurve<\/td>\n<\/tr>\n<tr>\n<th>Automatische bescherming<\/th>\n<td>Control part: Over voltage protection, over current protection, reverse connection protection, lightning arresterInverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc<\/td>\n<\/tr>\n<tr>\n<th>Weergave<\/th>\n<td>Aanraakscherm, LCD<\/td>\n<\/tr>\n<tr>\n<th>Inhoud controleren<\/th>\n<td>Spanning, stroom, vermogen van windturbine, spanning, stroom, vermogen van zonnepaneel, DC uitgangsspanning, stroom, vermogen, uitgangsvermogen van omvormer, * cumulatieve stroomopwekking, * stroomopwekking op elk moment, * rotatiesnelheid, * windsnelheid<\/td>\n<\/tr>\n<tr>\n<th>Beschermingsniveau<\/th>\n<td>IP20 (Binnen) IP65 (Buiten)<\/td>\n<\/tr>\n<tr>\n<th>Telematica<\/th>\n<td>RS485\/USB\/GPRS\/WIFI\/Ethernet (optioneel)<\/td>\n<\/tr>\n<tr>\n<th>Milieu<\/th>\n<td>Operating amb. Temp. &amp; Hum -30-60&deg;C,&lt;90% no condensation<\/td>\n<\/tr>\n<tr>\n<th>Geluid (1m)<\/th>\n<td>&lt;40 dB<\/td>\n<\/tr>\n<tr>\n<th>Koelmodus<\/th>\n<td>Geforceerde luchtkoeling<\/td>\n<\/tr>\n<tr>\n<th>Controller size \/ weight<\/th>\n<td>400*230*550mm 23kg<br \/>500*230*620mm 35kg<br \/>500*230*620mm 38kg<\/td>\n<\/tr>\n<tr>\n<th>Dump load size \/ weight<\/th>\n<td>690*450*530mm 36kg<br \/>980*880*540mm 70kg<br \/>980*880*540mm 70kg<\/td>\n<\/tr>\n<tr>\n<th>Inverter size \/ weight<\/th>\n<td>690*275*770mm 42kg<br \/>690*275*770mm 58kg<br \/>690*275*770mm 65kg<\/td>\n<\/tr>\n<\/tr>\n<tr>\n<tr>\n<th>Regelaar voor windturbines op het net<\/th>\n<td>WGMC3K220<br \/>WGMC5K220<\/td>\n<\/tr>\n<tr>\n<th>Stroom<\/th>\n<td>3KW<br \/>5KW<\/td>\n<\/tr>\n<tr>\n<th>Max. Stuurvermogen\/-stroom<\/th>\n<td>6KW\/20A<br \/>10KW\/34A<\/td>\n<\/tr>\n<tr>\n<th>Nominale spanning van windturbine (AC)<\/th>\n<td>220V<br \/>220V<\/td>\n<\/tr>\n<tr>\n<th>Bereik ingangsspanning<\/th>\n<td>AC<br \/>0-330V<br \/>0-330V<\/td>\n<\/tr>\n<tr>\n<th>DC<\/th>\n<td>0-450V<br \/>0-450V<\/td>\n<\/tr>\n<tr>\n<th>Remspanning (DC)<\/th>\n<td>Standaard<br \/>350V&plusmn;1%<br \/>350V&plusmn;1%<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>320-350V<br \/>320-350V<\/td>\n<\/tr>\n<tr>\n<th>Remstroom (DC)<\/th>\n<td>Standaard<br \/>15A<br \/>25A<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>0-15A<br \/>0-25A<\/td>\n<\/tr>\n<tr>\n<th>Remtijd<\/th>\n<td>Standaard<br \/>10-20 min<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>0-5000 min<\/td>\n<\/tr>\n<tr>\n<th>* Generator overspeed control<\/th>\n<td>Standaard<br \/>&gt;300 tpm\/min<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>0-1000 tpm\/min<\/td>\n<\/tr>\n<tr>\n<th>* Controle over windsnelheid<\/th>\n<td>Standaard<br \/>14 m\/s<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>0-45 m\/s<\/td>\n<\/tr>\n<tr>\n<th>Handmatige bediening<\/th>\n<td>Manual brake,*remote control brake (with communication function)<\/td>\n<\/tr>\n<tr>\n<th>Automatische controlefunctie<\/th>\n<td>Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake<\/td>\n<\/tr>\n<tr>\n<th>Nominaal vermogen (verhoogd)<\/th>\n<td>3KWp<br \/>3KWp<\/td>\n<\/tr>\n<tr>\n<th>Werkspanning (DC)<\/th>\n<td>320V \/ 400V<br \/>320V \/ 400V<\/td>\n<\/tr>\n<tr>\n<th>Bereik uitgangsspanning (DC)<\/th>\n<td>0-350V<br \/>0-350V<\/td>\n<\/tr>\n<tr>\n<th>Constante spanning (DC)<\/th>\n<td>Standaard<br \/>310V&plusmn;1%<br \/>310V&plusmn;1%<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>300-330V<br \/>300-330V<\/td>\n<\/tr>\n<tr>\n<th>Constante stroom (DC)<\/th>\n<td>Standaard<br \/>12A<br \/>20A<\/td>\n<\/tr>\n<tr>\n<th>Bereik instellen<\/th>\n<td>0-12A<br \/>0-20A<\/td>\n<\/tr>\n<tr>\n<th>Omvormer voor windturbines op het net<\/th>\n<td>DMWG3KTL<br \/>DMWG5KTL<\/td>\n<\/tr>\n<tr>\n<th>Nominaal uitgangsvermogen (AC)<\/th>\n<td>3KW<br \/>5KW<\/td>\n<\/tr>\n<tr>\n<th>Max. Uitgangsvermogen (AC)<\/th>\n<td>3.3KW<br \/>5.5KW<\/td>\n<\/tr>\n<tr>\n<th>Bereik ingangsspanning (DC)<\/th>\n<td>0-450V<br \/>0-450V<\/td>\n<\/tr>\n<tr>\n<th>MPPT Voltage range (DC)<\/th>\n<td>100V-400V<br \/>100V-400V<\/td>\n<\/tr>\n<tr>\n<th>Max. Ingangsstroom (DC)<\/th>\n<td>11.2A<br \/>18.7A<\/td>\n<\/tr>\n<tr>\n<th>Nominale stroom<\/th>\n<td>10.2A<br \/>17A<\/td>\n<\/tr>\n<tr>\n<th>THD Huidige harmonische<\/th>\n<td>&lt;3% (bij nominaal vermogen)<\/td>\n<\/tr>\n<tr>\n<th>Vermogensfactor<\/th>\n<td>&gt;0.99<\/td>\n<\/tr>\n<tr>\n<th>Max. effici\u00ebntie<\/th>\n<td>98%<\/td>\n<\/tr>\n<tr>\n<th>Toelaatbaar bereik netspanning (AC)<\/th>\n<td>110V\/120V\/220V (Single-phase)&plusmn;20%<\/td>\n<\/tr>\n<tr>\n<th>Toelaatbaar netfrequentiebereik<\/th>\n<td>50Hz\/60Hz\u00b110%<\/td>\n<\/tr>\n<tr>\n<th>Automatische bedrijfsomstandigheden<\/th>\n<td>DC input and power grid meet the requirements, the inverter operates automatically<\/td>\n<\/tr>\n<tr>\n<th>Opstarttijd na stroomuitval<\/th>\n<td>2min (instelbaar)<\/td>\n<\/tr>\n<tr>\n<th>Functie<\/th>\n<td>Gelijkrichting, DC-uitgang, uitgangsspanningsregeling, uitgangsstroomregeling, Dump Load-regeling, instelling regelparameters, instelling windturbinecurve<\/td>\n<\/tr>\n<tr>\n<th>Automatische bescherming<\/th>\n<td>Control part: Over voltage protection, over current protection, reverse connection protection, lightning arresterInverter part: Polarity reverse connection protection, short circuit protection, island effect protection,LVRT,overheat protection, overload protection, ground fault protection, etc<\/td>\n<\/tr>\n<tr>\n<th>Weergave<\/th>\n<td>Aanraakscherm, LCD<\/td>\n<\/tr>\n<tr>\n<th>Inhoud controleren<\/th>\n<td>Wind turbine voltage , current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed<\/td>\n<\/tr>\n<tr>\n<th>Beschermingsniveau<\/th>\n<td>IP20 (Binnen) IP65 (Buiten)<\/td>\n<\/tr>\n<tr>\n<th>Telematica<\/th>\n<td>RS485\/USB\/GPRS\/WIFI\/Ethernet (optioneel)<\/td>\n<\/tr>\n<tr>\n<th>Milieu<\/th>\n<td>Operating amb. Temp. &amp; Hum -30-60&deg;C,&lt;90% no condensation<\/td>\n<\/tr>\n<tr>\n<th>Geluid (1m)<\/th>\n<td>&lt;40 dB<\/td>\n<\/tr>\n<tr>\n<th>Koelmodus<\/th>\n<td>Geforceerde luchtkoeling<\/td>\n<\/tr>\n<tr>\n<th>Controller size \/ weight<\/th>\n<td>360*230*480mm 17kg<br \/>360*230*480mm 18kg<\/td>\n<\/tr>\n<tr>\n<th>Dump load size \/ weight<\/th>\n<td>400*400*250mm 12kg<br \/>600*450*380mm 28kg<\/td>\n<\/tr>\n<tr>\n<th>Inverter size \/ weight<\/th>\n<td>450*275*770mm 39kg<br \/>450*275*770mm 44kg<\/td>\n<\/tr>\n<\/tr>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Het systeem van de netwindturbine is samengesteld uit windturbine, netcontrolemechanisme, netomschakelaar, metingsapparaat, en machtsdistributiesysteem. De windenergie wordt omgezet in AC elektrische energie door de windturbine, en dan omgezet in gelijkstroom elektrische energie door het netcontrolemechanisme, en dan wordt gelijkstroom elektrische energie omgezet in...<\/p>","protected":false},"featured_media":4172,"template":"","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"product_brand":[],"product_cat":[27,71],"product_tag":[],"class_list":["post-4182","product","type-product","status-publish","has-post-thumbnail","product_cat-product","product_cat-renewable-power-electronics","first","instock","shipping-taxable","purchasable","product-type-simple","entry","content-bg","loop-entry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>All in One on Grid Wind Turbine Controller | Deming Power<\/title>\n<meta name=\"description\" content=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind. Made in China by Jinan Deming Power \u2014 OEM\/ODM, global shipping. Request a quote today.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/dminverter.com\/nl\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"All in One on Grid Wind Turbine Controller | Deming Power\" \/>\n<meta property=\"og:description\" content=\"All in One on Grid Wind Turbine Controller and Grid Tie Wind. Made in China by Jinan Deming Power \u2014 OEM\/ODM, global shipping. Request a quote today.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/dminverter.com\/nl\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-15T00:07:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_01-152.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"550\" \/>\n\t<meta property=\"og:image:height\" content=\"316\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/dminverter.com\\\/product\\\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\\\/\",\"url\":\"https:\\\/\\\/dminverter.com\\\/product\\\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\\\/\",\"name\":\"All in One on Grid Wind Turbine Controller | Deming Power\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dminverter.com\\\/ru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/dminverter.com\\\/product\\\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/dminverter.com\\\/product\\\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/dminverter.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/img_01-152.webp\",\"datePublished\":\"2026-04-05T03:22:33+00:00\",\"dateModified\":\"2026-09-15T00:07:26+00:00\",\"description\":\"All in One on Grid Wind Turbine Controller and Grid Tie Wind. Made in China by Jinan Deming Power \u2014 OEM\\\/ODM, global shipping. Request a quote today.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/dminverter.com\\\/product\\\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/dminverter.com\\\/product\\\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/dminverter.com\\\/product\\\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\\\/#primaryimage\",\"url\":\"https:\\\/\\\/dminverter.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/img_01-152.webp\",\"contentUrl\":\"https:\\\/\\\/dminverter.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/img_01-152.webp\",\"width\":550,\"height\":316,\"caption\":\"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/dminverter.com\\\/product\\\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/dminverter.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PRODUCTS\",\"item\":\"https:\\\/\\\/dminverter.com\\\/ru\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"5\u201330 kW All in One on Grid Wind Turbine Controller and Grid-Tie Inverter with CE\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/dminverter.com\\\/ru\\\/#website\",\"url\":\"https:\\\/\\\/dminverter.com\\\/ru\\\/\",\"name\":\"Jinan Deming Power Equipment Co., Ltd.\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/dminverter.com\\\/ru\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/dminverter.com\\\/ru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/dminverter.com\\\/ru\\\/#organization\",\"name\":\"Jinan Deming Power Equipment Co., Ltd.\",\"url\":\"https:\\\/\\\/dminverter.com\",\"logo\":\"https:\\\/\\\/dminverter.com\\\/wp-content\\\/uploads\\\/2024\\\/06\\\/deming-logo.png\",\"image\":{\"@id\":\"https:\\\/\\\/dminverter.com\\\/ru\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"alternateName\":\"Deming Power\",\"description\":\"Jinan Deming Power is a Chinese manufacturer of industrial-grade power conversion equipment: pure sine wave inverters (10 kW to 1 MW), solar hybrid \\\/ off-grid inverters, wind turbine inverters, energy storage bidirectional converters (PCS), DC\\\/DC converters and frequency converters. Established 2004, exporting to 120+ countries. OEM\\\/ODM, factory-direct quotes available.\",\"foundingDate\":\"2004\",\"foundingLocation\":{\"@type\":\"Place\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"No. 888, Mingtang Road, Lixia District\",\"addressLocality\":\"Jinan\",\"addressRegion\":\"Shandong\",\"postalCode\":\"250101\",\"addressCountry\":\"CN\"}},\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"No. 888, Mingtang Road, Lixia District\",\"addressLocality\":\"Jinan\",\"addressRegion\":\"Shandong\",\"postalCode\":\"250101\",\"addressCountry\":\"CN\"},\"email\":\"58298175@qq.com\",\"contactPoint\":[{\"@type\":\"ContactPoint\",\"contactType\":\"sales\",\"telephone\":\"+86-181-5931-0123\",\"email\":\"58298175@qq.com\",\"contactOption\":\"TollFree\",\"areaServed\":[\"CN\",\"US\",\"EU\",\"AU\",\"RU\",\"ES\",\"PL\",\"NL\",\"FR\",\"KZ\",\"AE\",\"NG\",\"ZA\",\"BR\",\"IN\",\"TH\",\"VN\",\"ID\",\"PK\",\"UZ\",\"KE\"],\"availableLanguage\":[\"en\",\"es\",\"fr\",\"pl\",\"nl\",\"ru\",\"zh\"]}],\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/jinan-deming-power\"],\"knowsAbout\":[\"Industrial Power Inverters\",\"Solar Hybrid Inverters\",\"Off-Grid Power Systems\",\"Wind Turbine Inverters\",\"Energy Storage Converters (PCS)\",\"Bidirectional DC-DC Converters\",\"Variable Frequency Power Supplies\",\"Wind-Solar Hybrid Systems\",\"Microgrid Solutions\"],\"award\":[\"High and New Technology Enterprise (recognized three times, 2015 \\\/ 2018 \\\/ 2024)\",\"Jinan Specialized, Refined, Differentiated and Innovative SME\",\"Member of the standing council of China Wind Energy Association\",\"Participant in the formulation of IEC international standards for small wind turbines\",\"5 National Invention Patents, 12 Utility Model Patents, 5 Software Copyrights\"],\"member\":[\"China Wind Energy Association (Standing Council Member)\",\"China Renewable Energy Society\"],\"areaServed\":{\"@type\":\"AdministrativeArea\",\"name\":\"120+ countries across Asia, Africa, Europe, Latin America and Oceania (80% of production exported)\"},\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":50,\"maxValue\":200}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"All in One on Grid Wind Turbine Controller | Deming Power","description":"All in One on Grid Wind Turbine Controller and Grid Tie Wind. Made in China by Jinan Deming Power \u2014 OEM\/ODM, global shipping. Request a quote today.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/dminverter.com\/nl\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/","og_locale":"nl_NL","og_type":"article","og_title":"All in One on Grid Wind Turbine Controller | Deming Power","og_description":"All in One on Grid Wind Turbine Controller and Grid Tie Wind. Made in China by Jinan Deming Power \u2014 OEM\/ODM, global shipping. Request a quote today.","og_url":"https:\/\/dminverter.com\/nl\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/","article_modified_time":"2026-09-15T00:07:26+00:00","og_image":[{"width":550,"height":316,"url":"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_01-152.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"10 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/dminverter.com\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/","url":"https:\/\/dminverter.com\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/","name":"All in One on Grid Wind Turbine Controller | Deming Power","isPartOf":{"@id":"https:\/\/dminverter.com\/ru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/dminverter.com\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/#primaryimage"},"image":{"@id":"https:\/\/dminverter.com\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/#primaryimage"},"thumbnailUrl":"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_01-152.webp","datePublished":"2026-04-05T03:22:33+00:00","dateModified":"2026-09-15T00:07:26+00:00","description":"All in One on Grid Wind Turbine Controller and Grid Tie Wind. Made in China by Jinan Deming Power \u2014 OEM\/ODM, global shipping. Request a quote today.","breadcrumb":{"@id":"https:\/\/dminverter.com\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/dminverter.com\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/dminverter.com\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/#primaryimage","url":"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_01-152.webp","contentUrl":"https:\/\/dminverter.com\/wp-content\/uploads\/2026\/04\/img_01-152.webp","width":550,"height":316,"caption":"All in One on Grid Wind Turbine Controller and Grid Tie Wind Gnerator Inverter Wind Power Inverter with CE 5kw 10kw"},{"@type":"BreadcrumbList","@id":"https:\/\/dminverter.com\/product\/all-in-one-on-grid-wind-turbine-controller-and-grid-tie-wind-gnerator-inverter-wind-power-inverter-with-ce-5kw-10kw-20kw-30kw\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/dminverter.com\/"},{"@type":"ListItem","position":2,"name":"PRODUCTS","item":"https:\/\/dminverter.com\/ru\/shop\/"},{"@type":"ListItem","position":3,"name":"5\u201330 kW All in One on Grid Wind Turbine Controller and Grid-Tie Inverter with CE"}]},{"@type":"WebSite","@id":"https:\/\/dminverter.com\/ru\/#website","url":"https:\/\/dminverter.com\/ru\/","name":"Jinan Deming Power Equipment Co, Ltd.","description":"","publisher":{"@id":"https:\/\/dminverter.com\/ru\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/dminverter.com\/ru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/dminverter.com\/ru\/#organization","name":"Jinan Deming Power Equipment Co, Ltd.","url":"https:\/\/dminverter.com","logo":"https:\/\/dminverter.com\/wp-content\/uploads\/2024\/06\/deming-logo.png","image":{"@id":"https:\/\/dminverter.com\/ru\/#\/schema\/logo\/image\/"},"alternateName":"Deming Power","description":"Jinan Deming Power is a Chinese manufacturer of industrial-grade power conversion equipment: pure sine wave inverters (10 kW to 1 MW), solar hybrid \/ off-grid inverters, wind turbine inverters, energy storage bidirectional converters (PCS), DC\/DC converters and frequency converters. Established 2004, exporting to 120+ countries. OEM\/ODM, factory-direct quotes available.","foundingDate":"2004","foundingLocation":{"@type":"Place","address":{"@type":"PostalAddress","streetAddress":"No. 888, Mingtang Road, Lixia District","addressLocality":"Jinan","addressRegion":"Shandong","postalCode":"250101","addressCountry":"CN"}},"address":{"@type":"PostalAddress","streetAddress":"No. 888, Mingtang Road, Lixia District","addressLocality":"Jinan","addressRegion":"Shandong","postalCode":"250101","addressCountry":"CN"},"email":"58298175@qq.com","contactPoint":[{"@type":"ContactPoint","contactType":"sales","telephone":"+86-181-5931-0123","email":"58298175@qq.com","contactOption":"TollFree","areaServed":["CN","US","EU","AU","RU","ES","PL","NL","FR","KZ","AE","NG","ZA","BR","IN","TH","VN","ID","PK","UZ","KE"],"availableLanguage":["en","es","fr","pl","nl","ru","zh"]}],"sameAs":["https:\/\/www.linkedin.com\/company\/jinan-deming-power"],"knowsAbout":["Industrial Power Inverters","Solar Hybrid Inverters","Off-Grid Power Systems","Wind Turbine Inverters","Energy Storage Converters (PCS)","Bidirectional DC-DC Converters","Variable Frequency Power Supplies","Wind-Solar Hybrid Systems","Microgrid Solutions"],"award":["High and New Technology Enterprise (recognized three times, 2015 \/ 2018 \/ 2024)","Jinan Specialized, Refined, Differentiated and Innovative SME","Member of the standing council of China Wind Energy Association","Participant in the formulation of IEC international standards for small wind turbines","5 National Invention Patents, 12 Utility Model Patents, 5 Software Copyrights"],"member":["China Wind Energy Association (Standing Council Member)","China Renewable Energy Society"],"areaServed":{"@type":"AdministrativeArea","name":"120+ countries across Asia, Africa, Europe, Latin America and Oceania (80% of production exported)"},"numberOfEmployees":{"@type":"QuantitativeValue","minValue":50,"maxValue":200}}]}},"_links":{"self":[{"href":"https:\/\/dminverter.com\/nl\/wp-json\/wp\/v2\/product\/4182","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dminverter.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/dminverter.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dminverter.com\/nl\/wp-json\/wp\/v2\/media\/4172"}],"wp:attachment":[{"href":"https:\/\/dminverter.com\/nl\/wp-json\/wp\/v2\/media?parent=4182"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/dminverter.com\/nl\/wp-json\/wp\/v2\/product_brand?post=4182"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/dminverter.com\/nl\/wp-json\/wp\/v2\/product_cat?post=4182"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/dminverter.com\/nl\/wp-json\/wp\/v2\/product_tag?post=4182"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}