td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Model’, ‘DMWG-50KS’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Isolation’, ‘Frequency transformer isolation’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Maximum DC input power’, ’55KWp’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Maximum input voltage allows the fan’, ‘800Vdc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Maximum Power Point Tracking (MPPT) range’, ‘450Vdc-780Vdc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Nominal AC output power’, ’50KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. AC output power’, ’55KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THD of AC current’, ‘<3%(Rated power)’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘>0.99’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. efficiency’, ‘94%’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Euro efficiency’, ‘92%’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Output rating voltage’, ‘380Vac 50HZ’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Allowed Grid Voltage Range’, ‘310~450Vac’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Allowed Grid Frequency Range’, ‘47.5~51.5Hz’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Internal power consumption an night’, ‘<10W’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatically put into operation conditions’, ‘DC input and power to meet the requirements, the inverter automatically run’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic restart after power failure time’, ‘2min’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection’, ‘Reverse polarity, short circuit, island, overheating and overload etc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Comm. interfaces’, ‘RS485(Modbus Agreement)’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Operating Temp.’, ‘-25ºC~+60ºC’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Relative humidity’, ‘0~90%,Non-condensing’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Altitude(m)’, ‘6000 meters (over 2000 mxa0with derating required)’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Cooling method’, ‘Forced air cooling’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise’, ‘≤60dB’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection degree’, ‘IP20(indoor)’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Communications monitoring’, ‘Inverter via RS485 communication for start-stop control and routine data monitoring’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Type’, ‘FKJ-GT-50KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wind turbine rated power’, ’50KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Wind turbine Max. power’, ‘100KW’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Function’, ‘Rectifier,charge, control’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display mode’, ‘LED’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display content’, ‘DC output voltage,’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘PWM constant voltage’, ‘≥650dc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘wind turbine 3-phase dump load voltage1’, ‘670±5Vdc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘three-phase dump load 1xa0delay time’, ’12-20 min’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘wind turbine 3-phase dump load voltage2’, ‘680±5Vdc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘three-phase dump load 2xa0delay time’, ’12-20 min’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘wind turbine 3-phase dump load voltage3’, ‘700±5Vdc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘three-phase dump load 3xa0delay time’, ’12-20 min’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Low-voltage’, ‘≤200Vdc’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘PWM dump load fuse’, ’63A’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Fuse of DC output’, ‘100A’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Self-provided connecting wire of the PWM dump load (mm²)’, ‘>10mm²’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Self-provided connecting wire of the dump load 1(mm²)’, ‘>10mm²’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Self-provided connecting wire of the dump load 2(mm²)’, ‘>10mm²’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Self-provided connecting wire of the dump load 3(mm²)’, ‘>10mm²’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Work environment temperature’, ‘-30-60°C’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Relative humidity’, ‘<90% No condensation’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘<40dB’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Degree of protection’, ‘IP20(Indoor)’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Cooling method’, ‘Forced air cooling’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘*Temperature compensation(optional)’, ‘-4mv/°C/2V,-35°C~+80°C,n Accuracy:±1°C’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size of the controller (mm)’, ‘690*590*1300 mm’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight of the controller’, ‘120Kg’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Size of the dump load (mm)’, ‘800*580*1300mmxa0xa0760*520*1200mm(2pcs)’]
td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Weight of the dump load’, ‘128Kg’]