50kw 100kw 200kw Hydroelectric Generation Three Phase Converter

50kw 100kw 200kw Hydroelectric Generation Three Phase Converter

Energy Producers Ltd
Categories:
2026-04-05

Overview Projects

Did you like this Work? Please Share

Product Description

Generator power converter DMGC50K DMGC100K DMGC200K
Generator rated power 50KW 100KW 200KW
Rated voltage of generator (AC) 400V 400V/690V 400V/690V
Input voltage range (AC) 0-550V 0-550V / 0-800V 0-550V / 0-800V
Rated output power (AC) 50KW 100KW 200KW
MPPT MPPT Voltage range (AC) 250-500V 250-500V/400-750V 250-500V/400-750V
Max. Input current (AC) 79A 158A/92A 317.5A/184A
Rated current (AC) 72A 144A/84A 288.6A/167.3A
THD Current harmonic <3%(At rated power)
 Power factor >0.99
 Max. efficiency 96%
Electrical structure Power frequency transformer
 Allowable grid voltage range (AC) 220V/380V/440V/480V (Three-phase)±20%
 Allowable grid frequency range 50Hz/60Hz±10%
 Automatic operation conditions AC input and power grid meet the requirements, and the power converter operates automatically
 Restart time after power failure 2min ( Adjustable)
General parameters
Function Rectification, wind turbine curve setting, adjustable output power
Automatic protection Reverse connection protection, short circuit protection, island effect protection, LVRT, overheat protection, overload protection, ground fault protection, lightning arrester, etc
Display Touch screen
Monitoring content Generator voltage, current, power, inverter output power, * cumulative power generation,
* power generation at any time
 Protection level IP20(Indoor)IP65 (Outdoors)
Telematics RS485/USB/GPRS/WIFI/Ethernet (Optional)
 Environment -30-60°C,<90%
Operating amb. Temp. & Hum  -30-60°C,<90% no condensation
 Noise (1m) <40dB
 Refrigeration mode  Forced air cooling
size / weight 750*600*1320mm   340kg 1460*860*1820mm    1.4t 1460*860*1820mm    1.6t

 

Specifications

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Customization:’, ‘Available’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Nature of Source Flow:’, ‘Active Inverter’]

th style=”border:1px solid #ccc;padding:10px;background:#f5f5f5;text-align:left;font-size:13px;font-weight:bold;” >[‘Certification:’, ‘ISO9001, CE’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Generatorxa0power converter’, ‘DMGC50K’, ‘DMGC100K’, ‘DMGC200K’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Generator rated power’, ’50KW’, ‘100KW’, ‘200KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated voltage of generator (AC)’, ‘400V’, ‘400V/690V’, ‘400V/690V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Input voltage range (AC)’, ‘0-550V’, ‘0-550V /xa00-800V’, ‘0-550V /xa00-800V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated output powerxa0(AC)’, ’50KW’, ‘100KW’, ‘200KW’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘MPPT MPPT Voltage rangexa0(AC)’, ‘250-500V’, ‘250-500V/400-750V’, ‘250-500V/400-750V’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. Input currentxa0(AC)’, ’79A’, ‘158A/92A’, ‘317.5A/184A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Rated currentxa0(AC)’, ’72A’, ‘144A/84A’, ‘288.6A/167.3A’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘THDxa0Current harmonic’, ‘<3%(At rated power)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Power factor’, ‘>0.99’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Max. efficiency’, ‘96%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Electrical structure’, ‘Power frequency transformer’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Allowable grid voltage range (AC)’, ‘220V/380V/440V/480Vxa0(Three-phase)±20%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Allowable grid frequency range’, ’50Hz/60Hz±10%’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic operation conditions’, ‘AC input and power grid meet the requirements, and the power converter operates automatically’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Restart time after power failure’, ‘2min (xa0Adjustable)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Function’, ‘Rectification, wind turbine curve setting,xa0adjustable output power’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Automatic protection’, ‘Reverse connection protection, short circuit protection, island effect protection,xa0LVRT,xa0overheat protection, overload protection, ground fault protection, lightning arrester,xa0etc’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Display’, ‘Touch screen’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Monitoring content’, ‘Generatorxa0voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Protection level’, ‘IP20(Indoor)IP65 (Outdoors)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Telematics’, ‘RS485/USB/GPRS/WIFI/Ethernet (Optional)’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Environment’, ‘-30-60°C,<90%Operating amb. Temp. & Hum xa0-30-60°C,<90% no condensation’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Noise (1m)’, ‘<40dB’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘Refrigeration mode’, ‘Forced air cooling’]

td style=”border:1px solid #ccc;padding:8px;font-size:12px;” >[‘ size / weight’, ‘750*600*1320mm xa0xa0340kg’, ‘1460*860*1820mm xa0xa0xa01.4t’, ‘1460*860*1820mmxa0xa0xa0xa01.6t’]

Key Features